Application: Test and Measurement
Jacket: no jacket
Insulation Material: no insulation
Conductor Material: no conductor
Brand Name: Techwin

Specifications

the following example is for you reference.


Features:1.Automatic Measurement Mode: Only by selecting the measurement wavelength, the
Measurement parameters are automatically set, and the trace data is automatically saved and
Automatically analyzed.
2.Multi-wavelength Measurement Mode: in the parameter setting, the wavelength can be
Automatically switched into the multi-wavelength measurement mode. under this mode, the
Analysis can be achieved on the attenuation state of the same fiber section under different
Wavelengths.
3.Trace Fixing Function: It can achieve the same-screen comparison and display of one trace
with another real-time trace or the trace under the average measurement, which is very useful
for the installation of multi-core fiber or the checking of the aged fiber in the optical fiber
Network already been installed.

Technical details:Technical Specifications 1
Wavelength (nm)  850/1300  1310/1550  1310/1490/1550  1310/1550/1625
Dynamic range (dB) 2 23/21  32/30  32/30/30  32/30/30 4
Pulse width (ns)
5, 20, 40,
80, 160,
320, 640,
1280
5, 20, 40, 80, 160, 320, 640, 1280, 2560, 5120, 10240, 20480
Event blind zone (m) 3 2m  2m
Attenuation blind zone (m) 3 9m  8m
Linearity (dB/dB)  0.05 dB/ dB
Loss threshold (dB)  0.05
Loss resolution ratio (dB)  0.01
Sampling resolution ratio
(m)
0.125 to 8
Sampling point  32K
Distance uncertainty (m)  (1 m + 510 -5 distance + sampling interval)
Distance scope (km)  0.3 to180
Typical real-time refreshing
Duration (s)
0.2
Memory capacity of trace  SD Card (2G), > 10000 pieces
Duration of measurement Defined by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable
General specification  Interface category
Dimension (HWD)  15023566 
Optical
Interface
FC/UPC (PC, and APC are
Selectable)
Weight  1.5kg  Data interface
USB interface, SD card
Interface
Temperature
Running temperature -10 to 50 
Memory temperature -40 to 70  Visible failure orientation VFL
Relative humidity  0% to 95% (non condensation)  Wavelength  650nm
Power supply
Lithium battery; continuing working
Duration 8 hours
Output power
(dBm)
-3
Warranty period  12 months 
Maximum
Testing distance
3km
Remarks: 1. the technical specification describes the ensured performance of the instrument when using typical PC model connector to
Measure. without considering the uncertainty caused by optical fiber refractivity.
2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time.
Dynamic range is the data measured under the condition of 180km/20480ns/3min.
3. Measuring conditions of blind zone: reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum
Pulse width.
4. Dynamic range measured when there is filter.


Package:Instrument, FC/PC Connector, Lithium Battery, Trace Manager Software CD, Data Cable, AC adaptor, Soft carrying
Case, Warranty card, CE certificate, Certificate of calibration, Quick reference guide.