Brand Name: | DukeTech |
---|---|
color: | white |
Theory: | 0 |
Resolution: | 0 |
Size: | 0 |
Model Number: | DKCSF MS-1U |
Place of Origin: | China (Mainland) |
Use: | Coal Mining |
Material: | Carbide |
Certification: | Other |
Type: | Bop |
Processing Type: | Other |
Machine Type: | Other |
After-sales Service Provided: | Engineers available to service machinery overseas |
Condition: | New |
Weight: | 100kg |
color: | white |
Quick Details
Specifications
the following example is for you reference.
1.Brief Introduction:
the Coal Spontaneous Combustion Underground Monitoring System of Duketech is used to monitor the gas content of O2, N2, H2, He,CO, CO2, CH4, C2H4, C2H6, C2H2,H2S,so2,temperature, pressure, and so on. the regularity of formation of multi-component index gases during spontaneous combustion of coal is detected, which provides technical support and theoretical support for the identification of early hidden danger characteristic information of spontaneous combustion of coal.It can be used as a monitoring system for large-scale coal spontaneous combustion test bench and sample test bench, as well as provides experimental conditions for a multi-direction science such as coal fire prevention and fire science and improves the efficiency of coal mine production.
2.Techincal parameters:
Response time:
According to channel integration time(C.I.T.)and gas replacement cycle,typical 10s to several minutes;single gas<10 s;flushing time:nine gases(water vapor)<120s
Detection Principle:
Spectroscopy (CO, CO2, CH4, C2H4, C2H6, C2H2, H2O, H2S, so2, pressure, etc.), Thermal Conductivity (O2,H2,He,N2), Semiconductor (Temperature);
Sampling method:
Extraction type, pumping length is not less than 6,000 meters;
Measurement range:
CO 0~1% CO2 0~5%
CH4 0~1% C2H40~1%
C2H60~1%C2H20~1%
H2O0~1%so2 0~1%
O2 0~25%N20~80%
Temperature:(-5-100)
Pressure:0~1000KPa
Detection Limit:
CO1ppm CO25ppm
CH4 0.5ppmC2H40.5ppm
C2H60.5ppmC2H20.5ppm
H2O100ppmSO20.5ppm
O2 0.1%N20.5%
Temperature and Pressure Resolution:
Temperature:0.5 Pressure:0.1KPa
Accuracy:2% measurement value
Monitoring bundle tube:
12, 24, 48, 64, customizable
Running time:24hour continuous monitoring or manual setting.
Standard:
Low Voltage Measurement Directive 2006/95/EC and electro magnetic EMC Directive2004/108/EC EN 50270: 2006, EN 61000-3-2: 2006, EN 61000-3-3: 1995 + A1: 2001 + A2: 2005, EN 61010-1: 2001
Safety standards:
EN61010-1 (2001), IEC 61010-1 (2001), CAN/CSA-C22.2 No. 61010-1 (2004)and UL 61010-1 (2004 incl. rev. 2005)
3.Performance features:
L Gases: CO, CO2, CH4, C2H4, C2H6, C2H2, H2O, H2S, so2, O2,H2,He, N2, temperature, pressure, etc.
L Detection limits of ppb, sub-ppm levels.
L Dust filter, single tube, bundle tube, shunt box, extraction pump, gas sampling control cabinet, monitoring computer,spectrum multi-gas analyzer, thermal conductivity multi-gas analyzer, print output equipment, network card, system software composition.
L Underground gas sampling and analysis system, including mine intrinsically safe substation, power box and supporting equipment.
L Ground data processing and sharing subsystem, including industrial computer, printer, etc.
L Ground analysis workstation: composed of spectrum multi-gas analyzer, thermal conductivity multi-gas analyzer, collecting workstation power supply, etc.