Usage: | Auto Testing Machine |
---|---|
Power: | Electronic |
Brand Name: | CME |
Warranty: | 3 |
weight: | 2500 |
Model Number: | KRD30 |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Functions and features:
Advanced control system: in the main interface that is remotely and Real-time controlled by computer fully automatically, what operator only needs To do is to enter simple numerical value, and the tester will launch to Complete the acceleration test accurately.
User-friendly interface: the control Interface can display real-time test curves, tolerance and test time.
A powerful test system that can perform multi-stage acceleration Consecutive test: it can perform multi-stage acceleration consecutive test depending On the requirements of specimens.
Reliable protection measures: it provides protection for open circuit, Overlimit and overspeed.
Diverse control methods are available: it can complete the test by manual Operation when automatic control is not needed or valid.
Convenient and speedy output system: when test comes to an end, the test
Report will be generated automatically and is able to be printed.
Model Parameters |
KRD3003 |
KRD3005 |
KRD3010 |
KRD3020 |
KRD302M |
KRD303M |
KRD304M |
KRD308M |
Max. Load (kg)/Position |
36 |
54 |
102 |
202 |
0.05N |
0.04N |
0.03N |
0.02N |
Acceleration (g) |
3500 |
5100 |
20020k |
30030k |
50040k |
50080k | ||
Max. Height for Specimen (mm) |
200 |
300 |
||||||
Installation Radius (mm) |
230 |
500 |
80100 | |||||
Max. Rotating Speed (R/Min) |
1400 |
450 |
15000 |
18500 |
21500 |
30000 | ||
Launch/Stop Time (Min) |
≤3 |
≤5 | ||||||
Continues Worktime (Min) |
60 |
30 |
5 | |||||
Acceleration Accuracy (%) |
≤3 | |||||||
Consumption Power (kVA) |
3 |
5 |
7.5 |
11 |
15 | |||
Overall Dimension (mm) |
110011001200 |
165013501100 |
100010001100 | |||||
Collector Ring |
15 rings 500V 5A |
12rings 500V 5A |
||||||
Weight (kg) |
1200 |
1600 |
2300 |
2500 |
1200 |
1500 | ||
Power Supply |
AC380V±10% | |||||||
Measurement & Control System |
Automatic computer control or manual control | |||||||
Remarks |
the current collector and the control precision can be in accordance the related standards or customer requirements | |||||||
Working Environment |
Temperature Range 040℃, Humidity≤80% (no condense) | |||||||
Standards |
MIL-STD-810F IEC68-2-7 |