Product Main

Quick Details

Usage: Impact Testing Machine
Power: Electronic
Brand Name: KRD201\KRD301\KRD311
Warranty: 3
weight: 2500

Specifications

       Mass, centroid and moment of inertia measurement Instrument for model airplane

Main technical index

  It is required to measure the centroid position of small-sized Aircraft in the x,y,z direction and the moment of inertia around the x,y,z Axis. the max. Dimension of the micro-sized aircraft measured is as follows: 5 Meters wingspan, 1 meter high, 3 meters long.

  the mass measured ranges from 500g to 25kg.

  the measurement accuracy: ≤±6g;

  the mass measurement accuracy: ≤±1mm when mass ranges from 5 to 25kg; ≤±2mm when mass ranges from 500g5kg.

  the moment of inertia measured ranges from 0.1kgto 10.0kg;

  the accuracy of moment of inertia is ≤±1%

       Mass, centroid and moment of inertia measurement Instrument for satellite momentum wheel

Main technical indexes:

  Measurement range of mass: 2kg10kg;

  Main measurement job: axial centroid of momentum wheel and the centroid of line box in the x,y,z direction.

  Working table size: 400mm400mm;

  Measurement accuracy of mass: <±0.08%;

  Measurement accuracy of centroid: <±0.1mm;

  Measurement range of moment of inertia: 100kgcm24000kgcm2;

  the fixture diameter range must meet the requirement for diameter of Fixture;

  Max. Outside diameter of specimen must meet the requirement for the Outline size.

  Measurement accuracy of moment of inertia: ±0.3%(±0.5% when Less than 500 kgcm2)

       Mass, centroid measurement system for INS(inertial Navigation system)

Main technical indexes:

 Measurement range of mass: 2kg10kg

 Measurement accuracy of mass:±3G

 Measurement accuracy of centroid in X Direction:±0.2mm

 Measurement accuracy of centroid in Y.Z Directions:±0.1mm


       Mass and centroid measurement system for seeker

Technical index

 Measurement range of mass: 2kg10kg;

 Measurement accuracy of mass:±3G;

 Accuracy of measured centroid in X Direction:±0.15mm;

 Accuracy of measured centroid in Y and Z Directions:±0.05mm

Key Features:

 All stainless-steel parts are assembled In the table to protect the device from rust.

 the inner measurement unit processed by Vibration absorption meets the requirement for transportation by vehicle.

 the box for transferring that goes with the system is used for long-distance transportation at any time.


       Mass, centroid and moment of inertia measurement system for stable targeting system

Key technical index

  Measured diameter range: φ15φ50;

  Measurement range of mass: 520kg;

  Measured moment of inertia range:100kgcm23000kgcm2

  Measurement accuracy of moment of inertia: ≤±0.5%(within all ranges)

  Measurement accuracy of mass: ±5g

  Measurement Accuracy of centroid: ±0.03mm for Revolving object, ±0.1mm for Non-revolving object.

       Mass, centroid measurement system for microbullet

Key technical indexes:

 Measurement range of mass: 50g1.5kg;

 Measurement accuracy of mass:±0.5g;

 Measurement accuracy of centroid:≤±0.2mm radial,≤±0.05mm longitudinal;

 the weight: less than 5kg

 Working table size:200mm long,120mm wide;

 Clamping outside diameter of specimen:Φ20Φ50mm;

 Clamping distance of specimen:200mm;

 Manual device to move up/down is Equipped.


       Moment of inertia measurement system for microbullet

Technical indexes of No.1 measurement system

  Moment of inertia range: 10gcm21kgcm2;

  Measurement accuracy of moment of inertia: ±1%;

  Total weight: less than 2kg;

  Overall size: the diameter of base is Φ100mm, 200mm high.

  Clamping outside diameter of specimen: Φ10 Φ30mm;

  Clamping distance of specimen: ≤150mm

Technical indexes of No.2 measurement system

  Moment of inertia range: 1kgcm2100kgcm2;

  Measurement accuracy of moment of inertia: ±1%;

  Total weight: less than 5kg;

  Overall size: the diameter of base is Φ200mm, 300mm high.

  Clamping outside diameter of specimen: Φ30 Φ70mm;

  Clamping distance of specimen: ≤250mm

       Product of inertia measurement system

Product of inertia of specimen which is of Asymmetric structure can be measured by measuring the moment of inertia via Swing.



as for this moment of inertia measurement System, the fixture is horizontally installed when ly, lz, and lyz are Measured, the fixture is installed at a 45° when Ixy and Ixz are measured, and the Fixture is installed vertically. There are 3 kinds of no-load situations, so it Is necessary to measure the tensor under 3 kinds of no-load conditions and 6 Kinds of load conditions, therefore, the measured tensors are ly under no load, Lx under no load, lxy under no load, ly under load, lz under load, lyz under load, Lxz under load, lxy under load, and lx under load.

Technical indexes

  Moment of inertia range: 0.05 kg0.5 kg;

  Measurement accuracy of moment of inertia: ±0.3%;

  Measurement accuracy of product of inertia: ±1%;

  Measurement accuracy of principle axis of inertia: ±20

  Output parameters are as follows:

L Six centric inertial tensors

L 9 direction cosines to determine where 3 principle axises of inertia are.

L 3 principle moments of inertia

KRD201KRD301KRD311 series of nonstandard mass centroid and moment of inertia measurement instrument