Brand Name: | GFUVE |
---|---|
certificate: | IEC |
Certification: | IEC |
Automatic Power Saver: | One Phase AC 100-265V |
Battery Bank Voltage: | 57.7V, 100V, 220V, 380V |
Model Number: | GF312D1 |
Place of Origin: | China (Mainland) |
AC Current output: | 200mA, 1A, 5A, 20A, 100A |
Frequency Output: | 40Hz-70Hz |
Power Factor: | -1 ~ 0 ~ 1 |
Harmonic: | 2-51times |
Power Pulse Output: | active pulse, reactive pulse |
Active power energy: | 0.05%RG |
Reactive power energy: | 0.1%RG |
Weight (kg): | 15 |
Relative humidity: | 35%-85% |
Quick Details
Specifications
the following example is for you reference.
Features:
- Accuracy class 0.05
- 0-20A/0-500V, 0-120A/0-500V
- Start testing and creep testing
- Reference standard and power source integrated
- Test by automatic or manual
- 7 inch TFT touch screen
- Weight light 15Kg
- Recorder 500 sets energy meter data
- Overload, short circuit, open circuit protection
Technical details:
Electrical parameters Accuracy class
0.05%, 0.1% Power supply
One Phase AC 100-265V, frequency 50/60Hz. AC Voltage output Range(U1,U2,U3)
57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)Adjustment range
(0-120)%RG(1) Adjust fineness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
0.01%/120s Distortion
0.3% (Non-capacitive load) Output load
Each phase 30VA Measuring accuracy
0.05%RG AC Current output Range (I1, I2, I3 )
200mA, 1A, 5A, 20A, 100A(optional) Adjustment range
(0-120)%RG Adjustment fineness
0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
<0.01%/120s Distortion
≤0.3% (Non-capacitive load) Output load
30VA Accuracy
0.05%RG Power output Active power output stability
<0.01%RG/120s Reactive power output stability
<0.02%RG/120s Active power measuring accuracy
0.05%RG Reactive power measuring accuracy
0.1%RG Phase Output Output adjustment range
0°-359.999° Output adjustment fineness
10, 1, 0.1, 0.01 as optional. Resolution
0.01° Accuracy
0.03° Power Factor Adjustment range
-1 ~ 0 ~ 1 Resolution
10, 1, 0.1, 0.01 as optional. Measurement accuracy
0. 0005 Frequency Output Adjustment range
40Hz-70Hz Output adjustment fineness
5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. Resolution
0.001Hz Accuracy
0.005Hz Voltage /Current/Harmonic Setting Harmonic number
2-51times Harmonic content
0-40% Harmonic phase
0-359.99 Harmonic setting accuracy
(10%±0.1%)RD(2) Power Energy Measurement Error Active power energy
0.05%RG Reactive power energy
0.1%RG Power Pulse Output Power pulse type
Active pulse, reactive pulse Active power pulse output
5V,10mA Power Pulse Input Energy pulse type
Support active and reactive pulse, the highest frequency
Power pulse input is 180K.Mechanical parameters Dimensions (WDH) (mm)
495x390x195 Weight (kg)
15 Environmental conditions Ambient temperature
-10°C to +50°C Relative humidity
35%-85% (1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.