Product Main

Quick Details

Brand Name: GFUVE
certificate: IEC
Certification: IEC
Automatic Power Saver: One Phase AC 100-265V
Battery Bank Voltage: 57.7V, 100V, 220V, 380V
Model Number: GF312D1
Place of Origin: China (Mainland)
AC Current output: 200mA, 1A, 5A, 20A, 100A
Frequency Output: 40Hz-70Hz
Power Factor: -1 ~ 0 ~ 1
Harmonic: 2-51times
Power Pulse Output: active pulse, reactive pulse
Active power energy: 0.05%RG
Reactive power energy: 0.1%RG
Weight (kg): 15
Relative humidity: 35%-85%

Specifications

the following example is for you reference.


Features:

  

  • Accuracy class 0.05
  • 0-20A/0-500V, 0-120A/0-500V
  • Start testing and creep testing
  • Reference standard and power source integrated
  • Test by automatic or manual
  • 7 inch TFT touch screen
  • Weight light 15Kg
  • Recorder 500 sets energy meter data
  • Overload, short circuit, open circuit protection


 

Technical details:

Electrical parameters
Accuracy class  0.05%, 0.1%
Power supply One Phase AC 100-265V, frequency 50/60Hz.
AC Voltage output
Range(U1,U2,U3) 57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range (0-120)%RG(1)
Adjust fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load Each phase 30VA
Measuring accuracy 0.05%RG
AC Current output
Range (I1, I2, I3 ) 200mA, 1A, 5A, 20A, 100A(optional)
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Output load 30VA
Accuracy 0.05%RG
Power output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.03°
Power Factor
Adjustment range -1 ~ 0 ~ 1
Resolution 10, 1, 0.1, 0.01 as optional.
Measurement accuracy 0. 0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type Active pulse, reactive pulse
Active power pulse output 5V,10mA
Power Pulse Input
Energy pulse type Support active and reactive pulse, the highest frequency
Power pulse input is 180K.
Mechanical parameters
Dimensions (WDH) (mm) 495x390x195
Weight (kg) 15
Environmental conditions
Ambient temperature -10°C to +50°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

 GF302D Class 05 Portable Three Phase KWH Meter Test Equipment