| Brand Name: | GFUVE |
|---|---|
| certificate: | IEC |
| Certification: | CNAS |
| Automatic Power Saver: | 220V/110V, 50/60Hz |
| Battery Bank Voltage: | 30-560V |
| Model Number: | GF312v2 |
| Place of Origin: | China (Mainland) |
| Accuracy class: | 0.05%, 0.1% |
| Power Supply: | External power, 220V/110V, 50/60Hz Phase voltage supply 45-450V, 50/60Hz Li-Battery supply |
| Voltage measurement: | 30-560V |
| Current measurement: | 0.01-10A |
| Range (clamp CT): | 5A,100A,500A,1000A,2000A (option) |
| Harmonic: | 2nd-51st |
| Resolution: | 7 inch TFT color (480*234) |
| Data storage qty: | 5000 |
| Communication with PC: | USB/RS232 |
| Dimensions (W*H*D) (mm): | 245*168870 |
Quick Details
Specifications
FEATURES
- High accuracy 0.05%
- Screen capture function
- Input two pulse signal for master and slave meter synchronously calibration
- Large size display screen, direct viewing and convenient
- Internal communication port for PC control
- Multiple power supply for different testing occasion
- Large capacity storage device for mass memory
| Electrical parameters | |
|---|---|
| Accuracy class | 0.05%, 0.1% |
| Power Supply | External power, 220V/110V, 50/60Hz Phase voltage supply 45-450V, 50/60Hz Li-Battery supply |
| Voltage measurement | |
| Range | 30-560V |
| Error | ±0.05% |
| Harmonic | 2nd-51st |
| Current measurement | |
| Range (direct connection) | 0.01-10A |
| Range (clamp CT) | 5A,100A,500A,1000A,2000A (option) |
| Error (direct connection) | ±0.05% |
| Error (clamp CT) | ±0.2% (5A, 100A ) ±0.5% (other) |
| Harmonic | 2nd-51st |
| Power measure error | |
| Active power (direct connection) | ±0.05% |
| Active power (clamp CT) | ±0.2% (5A, 100A) ±0.5% (other) |
| Reactive power (direct connection) | ±0.1% |
| Reactive power (clamp CT) | ±0.2% (5A, 100A) ±0.5% (other) |
| Energy measure error | |
| Active energy (direct connection) | ±0.05% |
| Active energy (clamp CT) | ±0.2% (5A, 100A) ±0.5% (other) |
| Reactive energy (direct connection) | ±0.1% |
| Reactive energy (clamp CT) | ±0.2% (5A, 100A) ±0.5% (other) |
| Phase angle | |
| Range | 0°-360° |
| Resolution | 0.01° |
| Error | ±0.05° |
| Frequency | |
| Range | 45Hz-65Hz |
| Resolution | 0.001Hz |
| Error | 0.002Hz |
| Pulse output | |
| Energy constant | 25000 |
| Pulse ratio | 1:1 |
| Output level | 5V |
| Pulse input | |
| Input channel | 2 |
| Input level | 5-10V |
| Input frequency | Max. 100Hz |
| Display | |
| Resolution | 7" TFT color (480234) |
| Function | |
| Vector diagram | Yes |
| Waveform | Yes |
| Energy accumulation | Yes |
| CT ratio test | Yes |
| Local parameter input | Yes |
| Wiring emulation | Yes |
| Self-calibration | Yes |
| Recorder check | Yes |
| Data storage | Yes |
| Data storage qty | 5000 |
| External extend memory | Yes |
| Screen printing | Yes |
| Communication port | USB/RS232 |
| Communication with PC | Yes |
| Upload data | Yes |
| External mini printer | Yes |
| External keyboard | Yes |
| Mechanical parameters | |
| Dimensions (WHD) (mm) | 24516870 |
| Weight (kg) | 1.8 |
| Environmental conditions | |
| Ambient temperature | -25°C to +45°C |
| Relative humidity | 30%-95% |