| Brand Name: | SNOVA |
|---|---|
| Rated Voltage: | 3-40.5V |
| application: | power distribution equipment |
| Material: | PC |
| name: | fault indicator |
Quick Details
Specifications
UserManual & Data sheet
SNV-EKL4Earth fault and short circuit indicator
Type: surface mounted
Optional:
1. SNV-EKL4, normal type without RS485 and outside AC220V input.
2) SNV-EKL4, communication type, with RS485 ,Modbus protocol,and with AC220V power input.
Description
SNV-EKL4 short circuit and earth fault indicator, it Widely used in various ring cabinets, high-voltage switch gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid. the use of cable type short circuit and grounding fault indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. the design uses electromagnetic induction, photoelectric conversion, signal optical fiber transmission and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability.
Equipped with fault remote transmission port, suitable for distribution network automation; Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 8 years); external structure using card or lock design, the whole machine is easy to load and unload.
Function character:
1) Intelligent detection of short-circuit and ground fault and through the corresponding LED on the panel to indicate fault.
2)Monitor panel designed with button, it isConvenient for reset or test.
3)the pulse width time of fault current can be set to prevent incorrect fault indication caused by surge current.
4)It can reset and detect the remote fault indication device remotely.
5)It can provide switch volume for external devices through remote contact.
6)It canChoose the reset time after fault happen (when purchase, it need to tell factory to set,default 8hours).
7)Remote fault indicating can be made by external lamp.
8)It canChoose the short circuit alarm current (when purchase, it need to tell factory to set).
9)Earth fault alarm current set in factory
10)Low battery display and alarm through press the " Test/reset" key by 3seconds.
Technology parameter
Voltage grade 3-40.5KV Battery life ≥8 year Frequency 50HZ/60HZ Low voltage alarm of battery ≤2.7V SHort circuit alarm current 150A~1200A SHort circuit sensor fiber length 3Meter, or customized Earthfault alarm current 20A~100A Earth fault sensor cable length 3Meter,or customized Alarm current accuracy ±10% Load fluctuation and escape pulse time setting SHort circuit 40ms,60ms,80ms,160ms (settable) Rated frequency withstand voltage 2KV/1min EArth fault Relay contact capacity ≤95W Work environment Temperature -40℃~+60℃ Reset time Settable 4H/8H/24/36H Humidity ≤95%RH Working power ER17505 Battery 3.6V/3500mAh Use for cable diameter ShOrt circuit CT(Fiber, Type S) A 20mm~40mm, Normally B 300mm~70mm customized Working current Standby state ≤10μA Earth fault sensor(Cable, type E) A 60mm~100mm Normally WOrking state ≤1mA Indicator protection level Monitor panel IP 40 B 80mm~130mm Customized SEnsor CT IP 65