Product Main

Quick Details

Best AC Voltage Accuracy: ±1.2 % + 3 digits
Minimum Operating Temperature: -10°C
Maximum Operating Temperature: +50°C
Width: 90mm
Absolute Maximum Temperature Measurement: +1200°C
Absolute Maximum Capacitance Measurement: 60mF
Multimeter Type: Handheld
Weight: 400g
Safety Category Level: CAT III, CAT IV
DC Current Measurement Resolution: 0.001A
Resistance Measurement Resolution: 100mΩ
Absolute Maximum DC Voltage Measurement: 1000V dc
Absolute Maximum Resistance Measurement: 60MΩ
Best AC Current Accuracy: ±1 % + 3 digits
Height: 190mm
Absolute Maximum AC Current Measurement: 10A ac
Best DC Current Accuracy: ±0.8 % + 3 digits
AC Current Measurement Resolution: 0.001A
Temperature Measurement Resolution: 0.1°C
Model Number p: CA 5273
True RMS: Yes
Best DC Voltage Accuracy: 0.2% + 2 cts
Display Type: Digital, LCD
Length: 45mm
AC Voltage Measurement Resolution: 0.1mV ac
Brand: Chauvin Arnoux
Safety Category Voltage: CAT III 1000 V, CAT IV 600 V
Dimensions: 90 x 45 x 190mm
Maximum Frequency: 50kHz
Absolute Maximum DC Current Measurement: 10A dc
DC Voltage Measurement Resolution: 0.1mV dc
Absolute Maximum AC Voltage Measurement: 1000V ac
Battery Type: 9 V, IEC 6LR61
Best Temperature Measurement Accuracy: ±0.5 % + 2 °C
Best Resistance Measurement Accuracy: ±1 % + 2 Digits
Best Capacitance Measurement Accuracy: ±1 % + 5 digits
Battery Life: 150 h
Functions Measured: AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Low Impedance Voltage, Resistance, Temperature
Capacitance Measurement Resolution: 1pF

Specifications

The CA 5273 is a comprehensive Multimeter for electrical maintenance of installations and small AC and DC machines, with a double 6,000-count backlit display and a 61+2-segment bargraph with remnant effect. The CA 5273 digital Multimeter is particularly compact, making it very easy to handle. The bargraph has a central zero
AC voltage measurement with low input impedance (voltage measurements for electrical and electrical engineering applications)

• CAT IV 600V / CAT III 1,000V
• TRMS measurements
• 12-bit TRMS fast acquisition & 5 measurements per second
• Measurement of the ionization current
• Bi-mode double 6,000-count backlit display and 61+2-segment bargraph (full scale / central zero)
• Auto AC/DC selection
• Automatic or manual range selection
• VLowZ low-impedance voltage measurement with low-pass filter
• 1,000 V
• 10 A
• Resistance / audible continuity
• Temperature
• Capacitance
• Relative and differential measurements
• Max / Min storage
• 3-year warranty