| Best AC Voltage Accuracy: | ±0.3 Reading + 0.05 Range % |
|---|---|
| Minimum Operating Temperature: | 0°C |
| Maximum Operating Temperature: | +55°C |
| Width: | 280mm |
| Absolute Maximum Capacitance Measurement: | 500µF |
| Multimeter Type: | Bench |
| Weight: | 2.7kg |
| Safety Category Level: | CAT I, CAT II |
| DC Current Measurement Resolution: | 100nA |
| Resistance Measurement Resolution: | 1mΩ |
| Absolute Maximum DC Voltage Measurement: | 1000V dc |
| Absolute Maximum Resistance Measurement: | 250MΩ |
| Best AC Current Accuracy: | ±0.05 Reading + 0.05 Range % |
| Height: | 88mm |
| Absolute Maximum AC Current Measurement: | 10A ac |
| Best DC Current Accuracy: | ±0.05 Reading + 0.010 Range % |
| AC Current Measurement Resolution: | 100nA |
| Temperature Measurement Resolution: | 0.1°C |
| True RMS: | Yes |
| Model Number p: | HMC8012 |
| Best DC Voltage Accuracy: | ±0.015 Reading +0.002% |
| Display Type: | TFT LCD |
| Length: | 222mm |
| AC Voltage Measurement Resolution: | 1µV |
| Brand: | Rohde & Schwarz |
| Safety Category Voltage: | 600 V, 1000 V |
| Dimensions: | 222 x 280 x 88mm |
| Maximum Frequency: | 999.9kHz |
| Absolute Maximum DC Current Measurement: | 10A dc |
| DC Voltage Measurement Resolution: | 1µV |
| Absolute Maximum AC Voltage Measurement: | 750V ac |
| Best Resistance Measurement Accuracy: | ±0.015 Reading + 0.002 Range % |
| Best Capacitance Measurement Accuracy: | ±1 Reading + 0.5 Range % |
| Functions Measured: | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Resistance |
| Capacitance Measurement Resolution: | 1pF |
Quick Details
Specifications
The HCM8012 Benchtop Digital Multimeter offers a 5 3/4 digit display (480000 points) resulting in measurement ranges that are four times higher without any requirement of range switching. It facilitates measurements in the measurement category II with a voltage of up to 600 V, as opposed to the standard of only 300 V in this instrument class. With the HMC8012, current measurements across the entire range can be performed with only one connector. This eliminates any manual switching during range transfers. Also, an integrated watt meter enables power measurement in the DC range.
Measurement range: DC to 100 kHz
Resolution: 1 μV, 100 nA, 1 mΩ, 1 pF, 1 Hz, 0.1 °C/F
Basic accuracy: 0.015 % (DC)
5-digit display (480 000 counts)
Simultaneous display of three measurement functions, e.g. DC + AC + statistics
Measurement rate: up to 200 values/s
Measurement functions: V (DC), I (DC), V (AC), I (AC), frequency, DC power, resistance (two and four wire), temperature (PT100/PT500/PT1000), capacitance, diode and continuity test
Mathematic functions: limit testing, min./max., average, offset, DC power, dB, dBm
Data logging to internal memory or USB flash drive in CSV format
Interfaces: USB-TMC/-VCP, Ethernet, LXI, IEEE-488 (GPIB)
SCPI commands largely compatible with Agilent 34410A (HMC8012-G)
HMC8012-G: HMC8012 incl. IEEE-488 (GPIB) interface
Measurement range: DC to 100 kHz
Resolution: 1 μV, 100 nA, 1 mΩ, 1 pF, 1 Hz, 0.1 °C/F
Basic accuracy: 0.015 % (DC)
5-digit display (480 000 counts)
Simultaneous display of three measurement functions, e.g. DC + AC + statistics
Measurement rate: up to 200 values/s
Measurement functions: V (DC), I (DC), V (AC), I (AC), frequency, DC power, resistance (two and four wire), temperature (PT100/PT500/PT1000), capacitance, diode and continuity test
Mathematic functions: limit testing, min./max., average, offset, DC power, dB, dBm
Data logging to internal memory or USB flash drive in CSV format
Interfaces: USB-TMC/-VCP, Ethernet, LXI, IEEE-488 (GPIB)
SCPI commands largely compatible with Agilent 34410A (HMC8012-G)
HMC8012-G: HMC8012 incl. IEEE-488 (GPIB) interface