| Best AC Voltage Accuracy: | ±(1.5% rdg + 8dgts) |
|---|---|
| Minimum Operating Temperature: | 0°C |
| Maximum Operating Temperature: | +40°C |
| Width: | 53mm |
| Absolute Maximum Temperature Measurement: | +1000°C |
| Clamp Meter Type: | Multifunction Clamp |
| Safety Category: | CAT II 1000 V; 10 A, CAT III 1000 V; 10 A, CAT IV 600 V |
| Maximum Conductor Size: | 57mm |
| Weight: | 585g |
| Power Source: | Battery |
| Safety Category Level: | CAT II, CAT III, CAT IV |
| DC Current Measurement Resolution: | 100mA |
| Resistance Measurement Resolution: | 100mΩ |
| Absolute Maximum DC Voltage Measurement: | 1000V dc |
| Absolute Maximum Resistance Measurement: | 66MΩ |
| Best AC Current Accuracy: | ±(2% rdg + 10dgts) |
| Height: | 281mm |
| Absolute Maximum AC Current Measurement: | 1.5kA ac |
| Best DC Current Accuracy: | ±(2% rdg + 5dgts) |
| AC Current Measurement Resolution: | 100mA |
| Temperature Measurement Resolution: | 1°C |
| True RMS: | Yes |
| Best DC Voltage Accuracy: | ±(0.5% rdg + 2dgts) |
| Display Type: | Bar Graphs, LCD |
| Jaw Capacity Busbars: | 57mm |
| Length: | 108mm |
| AC Voltage Measurement Resolution: | 1mV |
| Brand: | Martindale |
| Safety Category Voltage: | 1000 (CAT II & CAT III) V, 600 (CAT IV) V |
| Dimensions: | 108 x 53 x 281mm |
| Absolute Maximum DC Current Measurement: | 2kA dc |
| DC Voltage Measurement Resolution: | 1mV |
| Model Number: | MARCM87 |
| Absolute Maximum AC Voltage Measurement: | 750V ac |
| Battery Type: | 9V |
| Best Temperature Measurement Accuracy: | ±1.0% + 2 digits |
| Best Resistance Measurement Accuracy: | ±1.0% + 5 digits |
| Battery Life: | 75 h |
| Functions Measured: | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature |
Quick Details
Specifications
The CM87 can measure AC / DC current and can also measure AC / DC voltage plus testing procedures for resistance, capacitance, frequency, duty cycle, type K thermocouple temperature, continuity and diode.
Large size clamp meter with 57mm jaws
True RMS technology ensures accuracy on irregular waveforms
Tests AC current to 1500A and DC current to 2000A
AC voltage measurements to 750V and DC current measurements to 1000V
Tests resistance levels to 66MΩ
Capacitance measurements to 6.6mF
Frequency testing to 1MHz
Duty cycle from 5 to 95%
Temperature measurement using type K thermocouple (included) up to 1000°C (1832°F)
660Ω continuity test
Diode testing
6600 count LCD display with bargraph
Large size clamp meter with 57mm jaws
True RMS technology ensures accuracy on irregular waveforms
Tests AC current to 1500A and DC current to 2000A
AC voltage measurements to 750V and DC current measurements to 1000V
Tests resistance levels to 66MΩ
Capacitance measurements to 6.6mF
Frequency testing to 1MHz
Duty cycle from 5 to 95%
Temperature measurement using type K thermocouple (included) up to 1000°C (1832°F)
660Ω continuity test
Diode testing
6600 count LCD display with bargraph