Plug Type: | Type F - Schuko plug |
---|---|
Minimum Operating Temperature: | 0°C |
Maximum Operating Temperature: | +40°C |
Width: | 225mm |
Safety Category: | CAT III 600 V, CAT IV 300 V |
Earth Resistance Measurement: | Yes |
Maximum Continuity Resistance: | 9.99kΩ |
Continuity Test Current: | 15mA |
Weight: | 1.5kg |
Power Source: | Battery, Mains |
Minimum Continuity Resistance: | 300mΩ |
Safety Category Level: | CAT III, CAT IV |
Insulation Test Voltage: | 3700V |
IP Rating: | IP40, IP52 |
Height: | 140mm |
Maximum Voltage Measurement: | 600V |
Model Number p: | M503A |
Test Standards: | DIN VDE 0100-600, IEC 60364-6 |
Display Type: | LCD |
Length: | 130mm |
Brand: | Gossen Metrawatt |
Remote Switch Mode: | Yes |
RCD Test Type: | DC Selective |
Safety Category Voltage: | 300 V, 600 V |
Dimensions: | 130 x 225 x 140mm |
Test Type: | Wiring Polarity |
Loop Impedance Test Type: | Phase to Earth, Phase to Neutral |
Battery Type: | AA |
RCD Ramp Test: | Yes |
Quick Details
Specifications
Starter package PROFiTEST INTRO, consisting of PROFiTEST INTRO M520T, PRO-Schuko-Measuring-Adapter Z503K, PRO-Jumper Z503J, Universal Carrying Pouch F2010 Z700G, Battery Pack Master Z502H and charger Z502R.
Measurement of RLO, ZL-PE, ZL-N, RINS, RE, ΔU, phase
sequence and voltage
OFFSET Management RL-PE / RN-PE / RL-N
Measuring functions can be selected directly via the rotary switch
Testing of RCD types A, AC, F, B, B+, EV, MI and G/R, as well as SRCDs and PRCDs
Display of approved fuse types for electrical systems
Phase sequence measurement (including highest line-to-line voltage)
Measuring of contact voltage by Finger contact
Connection of an RFID reader or a barcode scanner
Individual measured value memory and memory structure setup
Help functions with wiring diagrams
Bidirectional data exchange via USB, DDS-CAD and epINSTROM
Measuring category: CAT III 600 V / CAT IV 300 V
International prompting (12 languages)
ETC software (Electrical Testing Center) for, amongst other functions, creating tree structures and documentation per ZVEH
Measurement of RLO, ZL-PE, ZL-N, RINS, RE, ΔU, phase
sequence and voltage
OFFSET Management RL-PE / RN-PE / RL-N
Measuring functions can be selected directly via the rotary switch
Testing of RCD types A, AC, F, B, B+, EV, MI and G/R, as well as SRCDs and PRCDs
Display of approved fuse types for electrical systems
Phase sequence measurement (including highest line-to-line voltage)
Measuring of contact voltage by Finger contact
Connection of an RFID reader or a barcode scanner
Individual measured value memory and memory structure setup
Help functions with wiring diagrams
Bidirectional data exchange via USB, DDS-CAD and epINSTROM
Measuring category: CAT III 600 V / CAT IV 300 V
International prompting (12 languages)
ETC software (Electrical Testing Center) for, amongst other functions, creating tree structures and documentation per ZVEH