| Plug Type: | Type F - Schuko plug |
|---|---|
| Minimum Operating Temperature: | -5°C |
| Maximum Operating Temperature: | +50°C |
| Width: | 225mm |
| Safety Category: | CAT II 1000 V, CAT III 1000 V, CAT IV 600 V |
| Earth Resistance Measurement: | Yes |
| Maximum Continuity Resistance: | 0.01kΩ |
| Continuity Test Current: | 15mA |
| Weight: | 1.5kg |
| Power Source: | Battery, Mains |
| Non-Tripping: | Yes |
| Minimum Continuity Resistance: | 1mΩ |
| Automatic RCD Test: | Yes |
| Safety Category Level: | CAT II, CAT III, CAT IV |
| Insulation Test Voltage: | 1000V |
| IP Rating: | IP40, IP52 |
| Height: | 140mm |
| Maximum Voltage Measurement: | 600V |
| Model Number p: | M520T |
| Test Standards: | EN 61557, IEC 61557, VDE 0413 |
| Display Type: | LCD |
| Length: | 130mm |
| Brand: | Gossen Metrawatt |
| Remote Switch Mode: | Yes |
| RCD Test Type: | AC Type, DC Selective |
| Safety Category Voltage: | 600 V, 1000 V |
| Dimensions: | 130 x 225 x 140mm |
| Test Type: | Wiring Polarity |
| Loop Impedance Test Type: | 3 Wire |
| Battery Type: | AA |
| RCD Ramp Test: | Yes |
Quick Details
Specifications
The PROFITEST INTRO provides professional electricians with a universal, compact and rugged, state-of-the-art measuring tool. The MT520T test instrument is capable of executing all measurements for testing the effectiveness of safety measures in electrical systems as required by IEC 60364-6 (DIN VDE 0100-600) and other countryspecific standards, and as specified in the individual sections of DIN EN 61557 (VDE 0413).
Measurement of RLO, ZL-PE, ZL-N, RINS, RE, ΔU, phase
sequence and voltage
OFFSET Management RL-PE / RN-PE / RL-N
Measuring functions can be selected directly via the rotary switch
Testing of RCD types A, AC, F, B, B+, EV, MI and G/R, as well as SRCDs and PRCDs
Display of approved fuse types for electrical systems
Phase sequence measurement (including highest line-to-line voltage)
Measuring of contact voltage by Finger contact
Connection of an RFID reader or a barcode scanner
Individual measured value memory and memory structure setup
Help functions with wiring diagrams
Bidirectional data exchange via USB, DDS-CAD and epINSTROM
Measuring category: CAT III 600 V / CAT IV 300 V
International prompting (12 languages)
ETC software (Electrical Testing Center) for, amongst other functions, creating tree structures and documentation per ZVEH
Measurement of RLO, ZL-PE, ZL-N, RINS, RE, ΔU, phase
sequence and voltage
OFFSET Management RL-PE / RN-PE / RL-N
Measuring functions can be selected directly via the rotary switch
Testing of RCD types A, AC, F, B, B+, EV, MI and G/R, as well as SRCDs and PRCDs
Display of approved fuse types for electrical systems
Phase sequence measurement (including highest line-to-line voltage)
Measuring of contact voltage by Finger contact
Connection of an RFID reader or a barcode scanner
Individual measured value memory and memory structure setup
Help functions with wiring diagrams
Bidirectional data exchange via USB, DDS-CAD and epINSTROM
Measuring category: CAT III 600 V / CAT IV 300 V
International prompting (12 languages)
ETC software (Electrical Testing Center) for, amongst other functions, creating tree structures and documentation per ZVEH