| Minimum Operating Temperature: | -20°C |
|---|---|
| Maximum Operating Temperature: | +50°C |
| Width: | 11.43mm |
| Maximum Humidity Measurement: | 90%RH |
| Weight: | 544g |
| Power Source: | Battery |
| Data Logging: | Yes |
| Carbon Monoxide Resolution: | 1ppm |
| Height: | 5.08mm |
| Maximum Carbon Dioxide Level: | 5000ppm |
| Temperature Measurement Resolution: | 0.1°C |
| Model Number p: | 975 |
| Maximum Carbon Monoxide Level: | 500ppm |
| Best Humidity Measurement Accuracy: | ±2 %RH |
| Display Type: | LCD - Backlit |
| Length: | 28.7mm |
| Minimum Carbon Monoxide Level: | 0ppm |
| Brand: | Fluke |
| Carbon Dioxide Resolution: | 1ppm |
| Dimensions: | 28.7 x 11.43 x 5.08mm |
| Humidity Measurement Resolution: | 1%RH |
| Maximum Temperature: | +50°C |
| Best Carbon Dioxide Accuracy: | ±2.75% + 75 ppm |
| Battery Type: | AA (Backup), Rechargeable Lithium-Ion (Primary) |
| Best Temperature Measurement Accuracy: | ±1.1 °C |
| Best Carbon Monoxide Accuracy: | ±3ppm |
| Minimum Carbon Dioxide Level: | 0ppm |
| Battery Life: | 11 h |
Quick Details
Specifications
The Fluke 975 AirMeter combines four air monitoring tools into one rugged and easy-to-use handheld tool. Use the Fluke 975 to verify efficient operation of heating, ventilation and air conditioning systems and test for dangerous carbon monoxide leaks in all types of buildings.
Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
Wet bulb and dew point temperature
% of outside air calculation
CO2 and CO field calibration feature
Self-test function at startup
Auto-backlight
Automatically compensates for barometric pressure changes
Min/Max/Average on all measured and calculated readings
Metric or standard units
Audible and visual threshold alarms
Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
Keypad lock for security
Includes FlukeView Forms? software
Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
Wet bulb and dew point temperature
% of outside air calculation
CO2 and CO field calibration feature
Self-test function at startup
Auto-backlight
Automatically compensates for barometric pressure changes
Min/Max/Average on all measured and calculated readings
Metric or standard units
Audible and visual threshold alarms
Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
Keypad lock for security
Includes FlukeView Forms? software