| Width: | 44.5mm |
|---|---|
| Current Range: | 12 → 18 A, 9 → 13 A |
| Brand: | Schneider Electric |
| Terminal Type: | Screw |
| Series: | GV2L |
| Breaking Capacity: | 4 kA |
| Range: | TeSys |
| Number of Poles: | 3P |
| Dimensions: | 89 x 44.5 x 97 mm |
| Voltage Rating: | 690 V |
| Length: | 89mm |
| Depth: | 97mm |
Quick Details
Specifications
Protecting your motors from faults such as an overload of high voltage, short circuits, or relay shutdowns is vital in an age where any downtime can be detrimental to a business and its operations. Schneider Electric has built a reliable, robust series known as the GV2-L series of Motor Protection Circuit Breaker to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents.
Magnetic motor circuit breaker.
Light-weight, robust and compact in its design, the GV2-L series is perfect for tight spaces.
Rotary knob control type.
Local and manual control when used on its own or combined with a contactor.
The Undervoltage trip enables the motor circuit breaker to be tripped if the voltage is lost.
Remote control tripping with built-in shunt trip.
The N/C position can be locked using 3 padlocks.
Spring terminal and screw clamp connectors.
Protection ratings & Safety features:
Live parts are inaccessible to any direct contact from external users, improving the safety of operations around the MPCB.
Magnetic trip technology to help protect the unit built into the circuit-breaker.
IEC 60947-1, IEC 60947-2, IEC 60947-4-1 standard ratings (full list in the datasheet).
Certified CSA (full list in the datasheet).
IK04 degree of protection.
Magnetic motor circuit breaker.
Light-weight, robust and compact in its design, the GV2-L series is perfect for tight spaces.
Rotary knob control type.
Local and manual control when used on its own or combined with a contactor.
The Undervoltage trip enables the motor circuit breaker to be tripped if the voltage is lost.
Remote control tripping with built-in shunt trip.
The N/C position can be locked using 3 padlocks.
Spring terminal and screw clamp connectors.
Protection ratings & Safety features:
Live parts are inaccessible to any direct contact from external users, improving the safety of operations around the MPCB.
Magnetic trip technology to help protect the unit built into the circuit-breaker.
IEC 60947-1, IEC 60947-2, IEC 60947-4-1 standard ratings (full list in the datasheet).
Certified CSA (full list in the datasheet).
IK04 degree of protection.