| Body Material: | Polyvinylidene Fluoride |
|---|---|
| Standards Met: | UL |
| Brand: | Cynergy3 |
| Minimum Operating Temperature: | -10°C |
| Maximum Operating Temperature: | +105°C |
| Switch Output: | NO/NC |
| Maximum dc Voltage: | 120V |
| Series: | RSF100 |
| Maximum Current: | 600 mA |
| Mounting Type: | Vertical |
| Gasket Material: | Viton |
| Device Type: | Float |
| Maximum ac Voltage: | 240V |
Quick Details
Specifications
A single switching point, miniature, vertical fluid level switch. These level switches can be mounted on the top or bottom of the tank and are installed with a compression seal so no access is required to the interior of the tank. Vertical level switches offer long-term reliability and minimal maintenance due to the simplistic construction. The switch can be changed from normally open to normally closed simply by removing and inverting the float.