| Mounting Style: | Compact |
|---|---|
| Brand: | Burkert |
| Minimum Operating Temperature: | -15°C |
| Maximum Operating Temperature: | +80°C |
| Supply Voltage: | 12 → 36 V dc |
| Pipe Diameter Range: | DN 6 → 50 mm |
| Control Output: | PNP |
| Electrical Connection: | Cable Plug |
Quick Details
Specifications
Designed for high temperature, continuous flow measurement of neutral, slightly aggressive, solid-free liquids, in hazardous environments.
For liquid flow measurement
Frequency output with pulse signal proportional to the flow rate
Interfaces via S030HT pipework flow adaptor with pressure-tight quarter turn mounting. Stainless steel construction permits high temperature (160°C) and pressure ranges (0-40barg)
Connects to remote display, transmitter, batch controller, PLC or SCADA
Typical applications are in hot process cleaning systems (CIP/SIP), hot water, cooling systems, industrial washing machines and chemical plants
Supply voltage: 12-30Vdc
Output signal Open collector, PNP: supply voltage; NPN: 0.2-30Vdc; max. frequency 250Hz
Accuracy up to ≤ 1% FS within 0.5 – 10 m/s (1.0 to 32.8 fps) – optimal velocity 2 – 3 m/s
Medium temperature: -20°C → 160°C
Fluid pressure range: PN40 (dependent on installation adaptor fitting)
Ingress protection: IP65 with cable plug
Body material: PPS, glass fibre reinforced
For liquid flow measurement
Frequency output with pulse signal proportional to the flow rate
Interfaces via S030HT pipework flow adaptor with pressure-tight quarter turn mounting. Stainless steel construction permits high temperature (160°C) and pressure ranges (0-40barg)
Connects to remote display, transmitter, batch controller, PLC or SCADA
Typical applications are in hot process cleaning systems (CIP/SIP), hot water, cooling systems, industrial washing machines and chemical plants
Supply voltage: 12-30Vdc
Output signal Open collector, PNP: supply voltage; NPN: 0.2-30Vdc; max. frequency 250Hz
Accuracy up to ≤ 1% FS within 0.5 – 10 m/s (1.0 to 32.8 fps) – optimal velocity 2 – 3 m/s
Medium temperature: -20°C → 160°C
Fluid pressure range: PN40 (dependent on installation adaptor fitting)
Ingress protection: IP65 with cable plug
Body material: PPS, glass fibre reinforced