| Display Screen: | LCD |
|---|---|
| Mounting Style: | Compact |
| Brand: | Honsberg |
| Minimum Operating Temperature: | -20°C |
| Maximum Operating Temperature: | +70°C |
| Maximum Flow Rate: | 1 → 150 (Water) cm³/s, 3 → 300 (Oil) cm³/s |
| Supply Voltage: | 18 → 30 V dc |
| Pipe Diameter Range: | 1/2 in |
| Control Output: | Analogue |
| Electrical Connection: | M12 Connector |
Quick Details
Specifications
Provides maximum and minimum flow rate data for use with flow/no-flow sensing applications
Flow setting ranges: 20 to 50cm/s
Programmed using the rotating programming ring which can be removed for security
Continual display (LCD; LED red) of flow rate as a percentage of maximum
Protection to IP67
Maximum 2s response time
1% repeat accuracy
Switching outputs: PNP, NPN - 300mA maximum
Five-pole, M12 plug connector
Supply voltage: 18 to 30Vdc
One analogue and two digital outputs
Minimum or maximum switching points with adjustable hysteresis
Programmable time delay
User-defined flow rate range