| Standards Met: | CE, cULus, ECOLAB |
|---|---|
| Output Type: | PNP |
| Communication Protocol: | IO-LINK |
| Brand: | Sick |
| Minimum Operating Temperature: | -40°C |
| Maximum Operating Temperature: | +60°C |
| Terminal Type: | 4-Pin Connector |
| IP Rating: | IP66, IP67, IP69K |
| Maximum dc Voltage: | 30V |
| Series: | W9-3 |
| Detection Type: | Background Suppression |
| Maximum Current: | |
| Detection Range: | 25 → 350 mm |
| Sensor Style: | Block |
| Mounting Type: | Panel Mount |
| Response Time: | <0.33 ms |
| Interface: | IO-Link |
| Housing Material: | VISTAL Plastic |
| Light Source: | LED |
| Electrical Connection: | 4-Pin M12 Connector |
Quick Details
Specifications
SICK W9-3 I/O-Link photoelectric sensors enclosed in a slim housing that reliably detects transparent objects. Small gaps between objects, highly transparent thin films, and vials with flow marks and severe lens defects can be reliably detected.
Setting the sensor requires a single press of the teach-in pushbutton. The sensor reliably adjusts for any changes to environmental conditions such as temperature, dust or dirt. The single-lens system sees through even the smallest of openings.
I/O-Link is the new communication standard for the integration of the sensors and actuators into automation systems. W9-3 I/O-Link can be parametrised and monitored via field bus. Preventative maintenance and service measures can be implemented, and changeover times for product or format changes can be significantly reduced.
Continuous threshold adaption (AutoAdapt)
Single-lens autocollimation optics
Simple setting either via teach-in pushbutton, cable or IO-Link
PinPoint LED technology
Flexible sensor settings, monitoring, advanced diagnostics, and visualization thanks to IO-Link
Setting the sensor requires a single press of the teach-in pushbutton. The sensor reliably adjusts for any changes to environmental conditions such as temperature, dust or dirt. The single-lens system sees through even the smallest of openings.
I/O-Link is the new communication standard for the integration of the sensors and actuators into automation systems. W9-3 I/O-Link can be parametrised and monitored via field bus. Preventative maintenance and service measures can be implemented, and changeover times for product or format changes can be significantly reduced.
Continuous threshold adaption (AutoAdapt)
Single-lens autocollimation optics
Simple setting either via teach-in pushbutton, cable or IO-Link
PinPoint LED technology
Flexible sensor settings, monitoring, advanced diagnostics, and visualization thanks to IO-Link