| Minimum Pressure Reading: | 0bar |
|---|---|
| Maximum Pressure Reading: | 10bar |
| Output Type: | Analogue |
| Brand: | WIKA |
| Maximum Pressure Setting: | 10bar |
| Minimum Operating Temperature: | -20°C |
| Maximum Operating Temperature: | +80°C |
| Hazardous Area Certification: | ATEX, IECEx |
| IP Rating: | IP65 |
| Minimum Pressure Setting: | 0bar |
| Series: | IS-3 |
| Supply Voltage: | 10 → 30 V dc |
| Response Time: | < 2 ms |
| Media Measured: | Gas, Liquid |
| Analogue Output: | 4 → 20 mA |
| Process Connection: | G1/4 |
| Accuracy: | 0.5 % |
| Housing Material: | Stainless Steel |
| Electrical Connection: | DIN 175301-803 A |
Quick Details
Specifications
Wika IS-3 range of hazardous area pressure transmitters with ATEX / IECEx approval for gas and liquid. Suitable for use within a vast range of demanding industrial & OEM pressure measurement applications. Resistant to vibration, shock & wide temperature variations thanks to a rugged exterior.
Designed for the highest industrial requirements and features ATEX, IECEx and EAC approvals.
Fully welded stainless steel wetted parts
IP65
Zero & span adjustment
Fast response < 2="">
Designed to withstand 100 million pressure cycles
Shock resistance per IEC 60068-2-27 to 1000g, vibration resistance per IEC 60068-2-6 to 20g
Designed for the highest industrial requirements and features ATEX, IECEx and EAC approvals.
Fully welded stainless steel wetted parts
IP65
Zero & span adjustment
Fast response < 2="">
Designed to withstand 100 million pressure cycles
Shock resistance per IEC 60068-2-27 to 1000g, vibration resistance per IEC 60068-2-6 to 20g