| Minimum Pressure Reading: | 0bar |
|---|---|
| Maximum Pressure Reading: | 400bar |
| Output Type: | 2 x PNP NO/NC Programmable |
| Brand: | Sick |
| Minimum Operating Temperature: | -20°C |
| Maximum Operating Temperature: | +80°C |
| IP Rating: | IP67 |
| Pressure Reading Type: | Relative |
| Maximum Current: | 250 mA |
| Supply Voltage: | 15 → 35 V dc |
| Response Time: | 3 ms |
| Media Measured: | Fluid, Gas |
| Process Connection: | G1/4 |
| Accuracy: | ±1 % |
| Housing Material: | ABS, PC, Stainless Steel, TPE |
| Electrical Connection: | M12 Connector |
Quick Details
Specifications
The PBS pressure switch sensor is designed for pressure monitoring and measurement in liquid and gas. The pressure sensor is for use in industrial applications such as machine and plant engineering. It is a pressure switch, transmitter and display in one device. The features of the PBS pressure sensor include: Switching point and reset point (Hysteresis), Switching delay, Min/max memory and password protection to prevent from unintended misadjustment,
Robust and compact design
Rotatable housing for flexible installation
Standard configuration of two switching outputs (PNP or NPN)
Safe and simple operation and set-up with three large buttons and clearly legible display
Insensitive against corrosive media
Robust and compact design
Rotatable housing for flexible installation
Standard configuration of two switching outputs (PNP or NPN)
Safe and simple operation and set-up with three large buttons and clearly legible display
Insensitive against corrosive media