Product Main

Quick Details

Minimum Pressure Reading: 0in wg
Maximum Pressure Reading: 14in wg
Output Type: Wheatstone Bridge
Brand: Honeywell
Minimum Operating Temperature: -40°C
Maximum Operating Temperature: +85°C
Pressure Reading Type: Differential
Supply Voltage: 10 V dc
Media Measured: Gas
Response Time: 1 ms
Analogue Output: 33 → 37 mV
Accuracy: ±3 %
Electrical Connection: PCB

Specifications

Miniature, very low pressure, un-amplified differential transducer with silicon diaphragm and ratiometric output.
High sensitivity and low null shift
Gauge measurements may be achieved by venting one port to atmosphere
Easily interchanged
Supplied with instruction leaflet
Media: P1 Port Dry Gases only; P2 Port Wetted Materials, Polyester housing, Epoxy adhesive, Silicon, Borosilicate Glass and Silicon-Glass bond
1ms maximum response time
Operating temp. -40°C to +85°C