Brand Name: Flowna
Accuracy: 0.2
Power Supply: 24VDC or 220VAC
output: USB data
Medium: gas vapor liquid
Model Number: FLXSJ-D2
Place of Origin: China (Mainland)

Specifications

with temperature compensation, with U disk interface, start / stop / reset button interface, 36VAC / 220VAC / 12 ~ 24VDC power supply

Data industrial LED flow meter flow computer batch wireless remote controllerData industrial LED flow meter flow computer batch wireless remote controllerData industrial LED flow meter flow computer batch wireless remote controller
Main Features

1. the error is less than 0.2%F.S, and it has the function of adjustment and digital filtering, which can help to reduce the error of sensor and transmitter, and improve the measurement and control precision of the system effectively.

2. Flow sensor suitable for current, voltage and pulse output.

3. 3 switch input, for start, recovery, and each accumulated value cleared.

4. Point control output, for large valve, small valve hierarchical control and instantaneous flow limit alarm.

5. Variable output can be instantaneous flow value in the form of standard current, voltage output, for other equipment use.

6. the 8 section linear correction can reduce the nonlinear error of the flow sensor.


7. Instantaneous flow can be chosen according to hour or minute.

8. Transparent, high-speed, efficient network communication interface, to achieve complete data transmission and control between computers and meters. the unique control transfer function enables the computer to control the working state and the output of the instrument directly. the time to read the measurement data is less than 10ms.

9. Provide test software, configuration software and application software technology support.

10. with a hardware clock print interface and print unit, to achieve manual, timing, alarm printing function. If the intelligent printing unit is selected, more than 1 printers can be shared by many meters.

11. 3 relay control output, for large valve, small valve hierarchical control and pump control.

Performance Index
Electrical performance index
Work power
A.24VDC, Power consumption ≤10W
B.85-220VAC, Power consumption ≤10W



Input
A.Thermocouple
Standard thermocouples -- K, E, B, J, N, T, S
B.Resistance
Standard thermal resistance -- Pt100, Pt1000
C.Current
0 ~ 10mA, 4 ~ 20mA
D.Voltage
0-5V, 1-5V
E.Pulse volume
Rectangular shape, sine wave and triangular wave,amplitude more than 4V,frequency 0 ~ 10KHz (or according to user requirements).





Output

Analog output
1.
DC 0~10mA(Load resistance≤750Ω)
2.
DC 4~20mA(Load resistance≤500Ω)
Control output
3 way relay output(Large valve, small valve, pump), AC220V/3A; DC24V/6A (resistive load)
Communication output
Tandard serial communication interface: RS-232C, RS-485, Ethernet
Feed output
DC24V, the load is less than or equal to 100mA; DC12V, the load is less than or equal to 200mA
Print
Serial thermal printer direct printing instrument data, real-time print material data, print data can be customized





Display mode
A. Backlit screen 128 x 64 dot matrix liquid crystal graphic display
B. Historical cumulative flow, instantaneous flow, medium temperature, medium density, flow (differential current, frequency), clock, alarm status
C. 0 ~ 999999 instantaneous flow value
D. 0 ~ 99999999.9999 cumulative value
E. -9999 ~ 9999 temperature compensation
F. -99999 ~ 999999 flow (pressure, frequency) value
G.Size: 152mm * 76mm
Measurement accuracy
Measurement accuracy: + 0.2%FS + 1 word or 0.5%FS + 1 word; frequency conversion accuracy: 1 pulse (LMS) is generally better than 0.2%


Protection mode
A.Power accumulated value time more than 20 years
B.Automatic reset, power supply under pressure
C.Abnormal automatic reset (Watch Dog)
D.Resettable fuse, short circuit protection