Product Main

Quick Details

Usage: Auto Testing Machine
Power: Electronic
Brand Name: CME
Warranty: 1 year
weight: 1000~6000
Model Number: KRD11
Place of Origin: China (Mainland)

Specifications

KRD17 series pneumatic bidirectional vertical shock test system is the new designed and developed for some large specimens that cannot or are not easy to turn over, especially for battery testing. It can complete vertical upward and downward shock tests. 

  • Air pressure drive, no pollution to the environment
  • One machine with multiple functions, one clamping, to complete the upward and downward shock and bump tests, with high efficiency
  • Built-in pneumatic brake mechanism, safe and reliable
  • One-machine management for control and measurement, convenient operation
  • Air springs and dampers are used to reduce vibration, and the installation is free of foundation


KRD17 Pneumatic Bidirectional Vertical Shock Test System

Technical Specifications

Model

Parameters

KRD1750

KRD17100

KRD17200

KRD17500

KRD17800

KRD171000

KRD172000

Rated Load (kg)

50

100

200

500

800

1000

2000

Table size (mm)

500500

600600

800800

10001000

12001200

15001500

20002000

Shock Direction

Downward

 

Peak Acc. (G)

 

Half-Sine

10-750

10-600

10-450

10-300

10-250

10-200

10-150

Post-Peak

Sawtooth

10-200

10-200

10-100

10-100

10-100

10-100

10-100

Trapezoid

15-200

15-200

15-100

15-100

15-60

15-60

15-50

Pulse Duration (ms)

Half-Sine

1.5-60

2-60

2.5-60

4-60

4.5-60

5-60

6-60

Post-Peak

Sawtooth

318

618

Trapezoid

318

318

618

Shock Direction

Upward

Shock Wave

Half Sine Wave

ShockPeakAcceleration(G)

15-350

15-300

15-200

15-150

15-100

15-100

15-75

Shock Pulse Duration(ms)

3.5-60

3.5-60

4-60

4.5-40

5.5-60

5.5-60

6-60

Overall Dimension (mm)

125012501600

125012501600

130013001700

135013501750

155015501750

165016501850

200020001900

Weight (kg)

3000

3200

3400

4000

5000

6000

8000

Power

AC220V10%,50Hz

Air Source

1MPa

Installation Conditions

No special foundation is required for installation, but a smooth cement floor is required. 800 ~ 1000mm working distance are reserved around the equipment

Working Environment

Temperature range 0 ~ 40; Humidity80%, non-condense

Standards

MIL-STD-810F       IEC68-2-27