Product Main

Quick Details

Coil Number: Autotransformer
Coil Structure: Toroidal
Phase: Three
Usage: Electronic
Brand Name: TYC
Model Number: TY-60KV
Place of Origin: China (Mainland)

Specifications





TY60KV High Voltage Generator 120KV 5mA High Voltage DC Pulse GeneratorI Introduction

TY-Series DC high voltage generator is based on Chinese industry Standard ZBF24003-90 "portable DC high voltage generator general technical Conditions" requirements,research, manufacturing.TY series DC high voltage generator is composed of medium Frequency inverter voltage double rectifier circuit, special PWM pulse width Modulation chip and high voltage high-power MOSFET device, and contains 0.75U Voltage output, current and voltage protection value setting, sound and light Alarm during protection and other functions.The instrument has the Characteristics of high precision, high stability, portability and full Function


DC hipot tester adopts High frequency PWM technology to make closed adjustment with high voltage Stability,small ripple  factor and fast Reliable protection circuit. the generator can endure direct discharge by Devices of large capacitance. It is small size and light light weight ,convenient for use

Full range of linear Smoothly adjusted voltage,with voltage regulation accuracy smaller than 0.1%; Voltage measurement accuracy is 0.5%, resolution 0.1V, Current measurement Accuracy is 0.5%, the min resolution  Control box 1μA.Shock resistance current Is  0. 1μA.

the Generator use AC 220V power supply (AC 220V± 10%, 50hz ±1%), the ripple Factor is less than 0.5%,and can be used for all-weather at the site




II Performance

L   Power: Voltage 220V±22V

L   Frequency: 50Hz or 60Hz;

L   Precision: ±1%;

L   Ripple factor: ≤1%;

L   Working style: Use continuously, every time not more than 30 minS;

L   Ambient Temperature: 0℃40℃;

L   Relative Humidity: ≤85%, no- Condensation.

III Technical parameter


Model/Specification

(kV/mA)

60/2

60/5

120/2

120/5

200/2

200/5

300/2

300/5

 

Output voltae(kV)

60

60

120

120

200

200

300

300

 

Output current(mA)

2

5

2

5

2

5

2

5

 

Output power(W)

120

300

240

600

400

1000

600

1500

 

Height ofTtimes pressure cylinder(m(m)

0.4

0.4

0.6

0.6

0.9

0.9

1.25

1.25

 

 

Voltage accuracy

Current accuracy

DRO ± (1.0% of reading ± 0.2KV)

DRO ± (1.0% of reading ± 2)

 

Ripple factor

≤0.5%

 

Voltage stability

Random fluctuations, Supply voltage Transformation ratio±10%≤1%

 

Overload capacity

No-load voltage can exceed 10% of the rated Voltage using ten minutes maximum charging current of 1.5 times the rated Current

 

Power supply

Single-phase current 50HZ 220V±10%

 

Working style

Intermittent use

 

A continuous period of up to 30 minutes

 

Working environment

Temperature: -10~40

 

Relative Humidity: Room temperature is 25Less than 85% (non-condensing)

 

Altitude: less than 1500m

 

with a capacitive load capacity

Test capacity is unlimited

 

1.5 times the rated current available to Charge

 

Structural features

Epoxy fiberglass  electrical Insulation times the pressure cylinder r

 

Air-insulated, no worry of leakage

 

 

Features of Operation Box

High Precision 0.75UDC--1mA One-touch buttons (Accuracy≤1.0%) most Suitable for MOA test

 

Overvoltage protection using DIP settings, at a glance

 

Vertical and Horizontal type of International standard chassis, the scene is more convenient