Coil Number: | Autotransformer |
---|---|
Coil Structure: | Toroidal |
Phase: | Three |
Usage: | Electronic |
Brand Name: | TYC |
Model Number: | TY-60KV |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
I Introduction
TY-Series DC high voltage generator is based on Chinese industry Standard ZBF24003-90 "portable DC high voltage generator general technical Conditions" requirements,research, manufacturing.TY series DC high voltage generator is composed of medium Frequency inverter voltage double rectifier circuit, special PWM pulse width Modulation chip and high voltage high-power MOSFET device, and contains 0.75U Voltage output, current and voltage protection value setting, sound and light Alarm during protection and other functions.The instrument has the Characteristics of high precision, high stability, portability and full Function
DC hipot tester adopts High frequency PWM technology to make closed adjustment with high voltage Stability,small ripple factor and fast Reliable protection circuit. the generator can endure direct discharge by Devices of large capacitance. It is small size and light light weight ,convenient for use
Full range of linear Smoothly adjusted voltage,with voltage regulation accuracy smaller than 0.1%; Voltage measurement accuracy is 0.5%, resolution 0.1V, Current measurement Accuracy is 0.5%, the min resolution Control box 1μA.Shock resistance current Is 0. 1μA.
the Generator use AC 220V power supply (AC 220V± 10%, 50hz ±1%), the ripple Factor is less than 0.5%,and can be used for all-weather at the site
II Performance
L Power: Voltage 220V±22V
L Frequency: 50Hz or 60Hz;
L Precision: ±1%;
L Ripple factor: ≤1%;
L Working style: Use continuously, every time not more than 30 minS;
L Ambient Temperature: 0℃40℃;
L Relative Humidity: ≤85%, no- Condensation.
III Technical parameter
Model/Specification (kV/mA) |
60/2 |
60/5 |
120/2 |
120/5 |
200/2 |
200/5 |
300/2 |
300/5 |
| |
Output voltae(kV) |
60 |
60 |
120 |
120 |
200 |
200 |
300 |
300 |
| |
Output current(mA) |
2 |
5 |
2 |
5 |
2 |
5 |
2 |
5 |
| |
Output power(W) |
120 |
300 |
240 |
600 |
400 |
1000 |
600 |
1500 |
| |
Height ofTtimes pressure cylinder(m(m) |
0.4 |
0.4 |
0.6 |
0.6 |
0.9 |
0.9 |
1.25 |
1.25 |
| |
|
Voltage accuracy Current accuracy |
DRO ± (1.0% of reading ± 0.2KV) DRO ± (1.0% of reading ± 2) | ||||||||
|
Ripple factor |
≤0.5% | ||||||||
|
Voltage stability |
Random fluctuations, Supply voltage Transformation ratio±10%≤1% | ||||||||
|
Overload capacity |
No-load voltage can exceed 10% of the rated Voltage using ten minutes maximum charging current of 1.5 times the rated Current | ||||||||
|
Power supply |
Single-phase current 50HZ 220V±10% | ||||||||
|
Working style |
Intermittent use | ||||||||
|
A continuous period of up to 30 minutes | |||||||||
|
Working environment |
Temperature: -10~40℃ | ||||||||
|
Relative Humidity: Room temperature is 25℃Less than 85% (non-condensing) | |||||||||
|
Altitude: less than 1500m | |||||||||
|
with a capacitive load capacity |
Test capacity is unlimited | ||||||||
|
1.5 times the rated current available to Charge | |||||||||
|
Structural features |
Epoxy fiberglass electrical Insulation times the pressure cylinder r | ||||||||
|
Air-insulated, no worry of leakage | |||||||||
|
Features of Operation Box |
High Precision 0.75UDC--1mA One-touch buttons (Accuracy≤1.0%) most Suitable for MOA test | ||||||||
|
Overvoltage protection using DIP settings, at a glance | |||||||||
|
Vertical and Horizontal type of International standard chassis, the scene is more convenient |