Product Main

Quick Details

Brand Name: gdmk
color: black
Elongation at Break: Power supplyAC 220V
Min. Bending Radius: Harmonic adaptation 3%
Consistency of rod: Weight35 kg
Model Number: TKJS
Place of Origin: China (Mainland)

Specifications

Product IntroductionTKJS Tan Delta Tester Transformer tester

TKJS Tan Delta Test Set is a kind of instrument with high precision fully automatic measuring the dielectric loss tangent and capacitance of various high voltage electrical equipments in the power plants and substations. the adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.

the instrument is equipped with high voltage step-up transformer. Besides it takes security measures like zero-cross closing lightning protection etc. during the experiment different levels of high voltage ranging from 0.5KV to 10kV are outputted. the instrument has the advantages of convenient and safe operation.

: Dielectric loss tester anti-interference dielectric loss tester automatic dielectric loss tester dissimilar frequency dielectric loss tester dissimilar frequency dielectric loss tester anti-interference dielectric loss tester automatic dielectric loss tester


Product Characteristics
  • 1, the adoption of frequency conversion technology could ensure the accurate measurement in the interference of strong electric field.

  • 2, the whole process is measured automatically through microcomputer.

  • 3, It could measure non-grounded or grounded high voltage equipments adopting positive and negative connection method. Besides it could measure the tgδ of capacitor voltage transformer and capacitance of main capacitor C1and C2.

  • 4, under the circumstance of oil dielectric loss ≥ 0.01% with oil cup positive wiring can be used to measure the dielectric loss of oil.

  • 5, the instrument has the advantages of convenient and safe operation.

  • 6, it takes security measures like zero-cross closing lightning protection etc.


   Product Parameters
Technical parameters
High voltage output 0.5~10kV
Increasing by 500V for each level a total of 20 levels capacity: 1500VA
Accuracy Tgδ: ± (reading *1.5% +0.06%)
Cx: ± (reading * 1.5% +5 PF)
Resolution Tgδ: 0.01%
Cx: 1pF
Measuring range 0.01% <tgδ <100%
3PF <Cx <60000PF
When it is 10kV, Cx ≤ 30000PF
When it is 5kV, Cx ≤ 60000PF
Power supply AC 220V ± 10%, 50 ± 1Hz
Measuring method A.Working frequency: 50Hz
B.Different frequency:45Hz/55Hz Automatic frequency conversion
Harmonic adaptation ≤ 3%
Application condition -15 ℃50 ℃ Relative humidity <80%
Dimension 460 (L) 345 (W) 350 (H)
Weight 35 kg