Brand Name: | gdmk |
---|---|
color: | write |
Elongation at Break: | made in China |
Min. Bending Radius: | power system |
Consistency of rod: | testing the insulated level |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Product description:
the test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage
Technical index:
Model |
Capacity (KVA) |
High Frequency Voltage Output Voltage (KV) |
High Frequency Voltage Output Current(mA) |
Low Frequency Voltage input |
Change |
Tempera- ture(℃) raised/ 30 minute | |
V |
A | ||||||
YD(G)-1.5 |
1.5 |
50 |
30 |
200 |
7.5 |
500 |
10 |
YD(G)-3 |
3 |
50 |
60 |
200 |
15 |
500 |
10 |
YD(G)-5 |
5 |
50 |
100 |
200 |
25 |
500 |
10 |
YD(G)-10 |
10 |
50 |
200 |
220/380 |
50/26 |
500 |
10 |
YD(G)-20 |
20 |
50 |
400 |
380 |
53 |
500 |
10 |
YD(G)-30 |
30 |
50 |
600 |
380 |
79 |
500 |
10 |
YD(G)-40 |
40 |
50 |
800 |
380 |
105 |
500 |
10 |
YD(G)-50 |
50 |
50 |
1000 |
380 |
132 |
500 |
10 |
YD(G)-100 |
100 |
100 |
100 |
500 |
263 |
1000 |
10 |
YD(G)-150 |
150 |
100 |
1500 |
500 |
300 |
1000 |
10 |
YD(G)-200 |
200 |
100 |
2000 |
500 |
400 |
1000 |
10 |
1. Technical parameters of HZJ (G) series alternating current test transformers
Model |
Capacity (KVA) |
High Frequency Voltage Output (KV) |
High Frequency Voltage Current (Ma) |
Low pressure input | Change |
Tempera- ture(℃) raised/ 30 Minute | |||
AC |
DC |
AC | DC | V |
A | ||||
TDM(G)-1.5 |
1.5 |
50 |
70 |
30 |
15 |
200 |
7.5 |
500 |
10 |
TDM(G)-3 |
3 |
50 |
70 |
60 |
15 |
200 |
15 |
500 |
10 |
TDM(G)-5 |
5 |
50 |
70 |
100 |
15 |
200/380 |
25 |
500 |
10 |
TDM(G)-10 |
10 |
50 |
70 |
200 |
100 |
380 |
50/26 |
500 |
10 |
TDM(G)-20 |
20 |
50 |
70 |
400 |
100 |
380 |
53 |
500 |
10 |
TDM(G)-30 |
30 |
50 |
70 |
600 |
100 |
380 |
79 |
500 |
10 |
TDM(G)-40 |
40 |
50 |
70 |
800 |
100 |
380 |
105 |
500 |
10 |
TDM(G)-50 |
50 |
50 |
70 |
1000 |
100 |
380 |
132 |
500 |
10 |
TDM(G)-5 |
5 |
100 |
140 |
100 |
50 |
200/380 |
25 |
1000 |
10 |
TDM(G)-10 |
10 |
100 |
140 |
200 |
100 |
380 |
50/26 |
1000 |
10 |
TDM(G)-20 |
20 |
100 |
140 |
300 |
100 |
380 |
53 |
1000 |
10 |
TDM(G)-30 |
30 |
100 |
140 |
400 |
100 |
380 |
79 |
1000 |
10 |
TDM(G)-40 |
40 |
100 |
140 |
600 |
100 |
380 |
105 |
1000 |
10 |
TDM(G)-50 | 50 |
100 |
140 |
1000 |
100 |
380 |
132 |
1000 |
10 |
2. Technical parameters of TDM (G) alternating and direct current test
Feature:
They make up of the high quality cold rolling silicon steel piece by YD (G) alternating current test transformer, TDM (G) alternating and direct current amphibious light high voltage test transformer. The winding is the concentric pagoda and multilayer cylindrical type, low-voltage winding in inner, high-voltage winding in outside; Outer cover is portable which has characteristics, such as volume smallness, weight light, the shape prettiness and move
Convenience and so on.