After-sales Service Provided: | Engineers available to service machinery overseas |
---|---|
Certification: | CE ISO |
Weight: | 950KG |
Brand Name: | ASSEN |
Condition: | New |
Dimension(L*W*H): | 1880*1750*1880mm |
Voltage: | 400,380,220 |
Usage: | Transformer Oil |
Model Number: | ZYD-100 |
Place of Origin: | China (Mainland) |
Working Pressure: | 0.4Mpa |
Flow: | 6000LPH |
name: | transformer oil filtration |
Quick Details
Specifications
ZYD mobile transformer oil filtration process Serves to improve the properties of insulating oil. It eliminates the acid Nature, over moisture, traces of water, dissolved gases, and particulate matter from the insulating oil effectively and rapidly. the bottom line of this Purification process is to enhance the performance level of transformers, Circuit breakers, mutual inductor, cables, and capacitors. All these equipment and machinery use an insulating system.
after Treatment
Moisture |
PPM |
≤3 |
Gas content |
% |
≤0.01 |
Impurity size |
μ |
≤1 (no free Carbon) |
Breakdown voltage |
kV |
≥75 |
IFT |
Dynes/cm |
≥40 |
Acid value |
MgKOH/g |
≤0.03 |
Dielectric loss Factors |
Tgδ(90°C) |
≤0.001 |
Technical Data
Parameters |
Unit |
ZYD-30 |
ZYD-50 |
ZYD-100 |
ZYD-150 |
ZYD-200 |
ZYD-250 |
ZYD-300 | |
Flow rate |
L/min |
30 |
50 |
100 |
150 |
200 |
250 |
300 | |
Working vacuum |
MPa |
0.080.099 | |||||||
Working Pressure |
MPa |
≤0.3 | |||||||
Temperature Range |
℃ |
2080 | |||||||
Power |
Three Phase 50HZ380V(as per the customer's Requirements) | ||||||||
Working Noise |
dB(A) |
75 |
75 |
75 |
80 |
80 |
80 |
80 | |
Heating Power |
kW |
30 |
30 |
45 |
60 |
75 |
90 |
120 | |
Total Power |
kW |
35.5 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 | |
Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 | |
Weight |
kg |
600 |
800 |
1050 |
1400 |
1800 |
2000 |
2200 | |
Overall |
Length |
mm |
1050 |
1100 |
1200 |
1450 |
1600 |
1800 |
1900 |
Width |
mm |
750 |
800 |
950 |
950 |
1100 |
1200 |
1200 | |
Height |
mm |
1350 |
1400 |
1500 |
1650 |
1800 |
1900 |
1900 |
Functions:
1. Dehydration, degassing and
Impurity removal of 110-1100KV main transformer insulation oil.
2. Acetylene removal of 110-1100KV
Main transformer insulation oil.
3. Vacuum drying of 110-1100KV main
Transformer insulation oil.
4. It can remove not only 100% free
Water and 99.9% dissolve water, but also 100% free gas and 98% dissolve gas.
5. Customized parts: PLC, frequency
Conversion technology, trailer and so on.
6. Advantages and characteristics
Please contact Assen for more details.