Product Main

Quick Details

Usage: Portable generator
Power: Electronic
Brand Name: GOLD
Warranty: 1 years
weight: 50kg
Model Number: GD-SLQ
Place of Origin: China (Mainland)

Specifications

Continuous Running Primary Current Injector Tester 5000A Transformer Injector Testing Equipment Why Primary Injection Tests? this type of test involves the entire circuit current transformer primary and secondary Wingdings, relay coils, trip and alarm circuits, and all intervening wiring are checked. There is no need to disturb wiring, which obviates the hazard of open-circuiting current transformers, and there is generally no need for any switching in the current transformer or relay circuits. Typical applications of primary injection testing

Besides the trip test of the complete loop to determine the integrity of the whole secondary protection circuit, other typical primary injection testing applications are:

Checking that the MV/HV/LV circuit breakers trip in response to an overcurrent.

Checking of CT/VT/PT ratios and polarities, to determine that the relationship between primary current and secondary current seen by the relay is correct.

Checking the correct wiring of the protection system, and that all protective devices are properly connected.

Checking of overcurrent and earth fault relays through primary injection testing.

Checking of CT circuits, to verify that all switches and protective relays receive the proper current at the proper angle as expected.

Testing of reclosers and sectionalizers.

Thermal tests on busbars, switchgear and electrical panels.

Testing ground grid installations.

Product Description

  Introduction

   ---Continuous Running Primary Current Injector Tester 5000A Transformer Injector Testing Equipment

SLQ is an essential equipment used for electrical debugging to generate high current, which be widely used in power plants, power distribution stations, electrical plants, scientific research, laboratories and other units.

It is a short-term or intermittent work device and characterized by small size, light weight, good performance, easy use and maintenance.

SLQ Features

   ---Continuous Running Primary Current Injector Tester 5000A Transformer Injector Testing Equipment

Two ammeters, can supervise different measurement range.

with indicator lighting and button, easy to operate

Incorporated and dividable structure, easy to move.

the equipment capacity is designed based on 5-minute short-term work system. for intermittent work, working time should be less than 2.5 minutes, before continuing to work it should be shut down for 10 minutes so that all parts of the machine can cool down.

SLQ Specifications

   ---Continuous Running Primary Current Injector Tester 5000A Transformer Injector Testing Equipment
Continuous Running Primary Current Injector Tester 5000A Transformer Injector Testing Equipment

Continuous Running Primary Current Injector Tester 5000A Transformer Injector Testing EquipmentContinuous Running Primary Current Injector Tester 5000A Transformer Injector Testing EquipmentContinuous Running Primary Current Injector Tester 5000A Transformer Injector Testing EquipmentContinuous Running Primary Current Injector Tester 5000A Transformer Injector Testing Equipment