Product Main

Quick Details

Usage: GDBC-901
Power: Electronic
Brand Name: GOLD
Warranty: 1 years
weight: 20kg
Model Number: GDBC-901
Place of Origin: China (Mainland)

Specifications

IEC79-1/IEC60044  Transformer Polarity Tester and Terminal Blok Transformer TTR Tester 

 

What is a transformer Turns Ratio tester?


 

A transformer turns ratio test confirms ratio accuracy of a transformer. the test ensures the correct ratio of both primary turns and secondary turns. It can also help to identify issues related to tap-changer performance, shorted turns, incorrect winding connections, and open windings. Due to the many benefits a transformer turns ratio test can reap, it is crucial and also within your best interest to have your transformer tested frequently.

There are a multitude of reasons a Transformer Turns Ratio Test Set might need re-calibration. while using in service, the windings of the test set can become damaged or deteriorated, resulting in spikes, surges, contamination, faults or other unintended consequences. these side effects of a lack of calibration can have a costly or even damaging effect on those using the test set.

in this white paper, we will cover the basics of transformer turns ratio test sets, the benefits and frequency of calibration, a brief overview of how to calibrate a test set and finally, how to choose a calibration lab for your Transform Turns Ratio Test Set.

Product Description

GDBC-901 Transformer Polarity Tester and Terminal Blok Transformer TTR TesterApplication scenarios

IEC791IEC60044 Transformer Polarity Tester and Terminal B Metal CNC cutting machine CNC WoodRouter VCT4030C

GDBC-901 Transformer Polarity Tester and Terminal Blok Transformer TTR Tester Introduction

  • GDBC-901 is applied to measure the voltage ratio of three or single phase transformer. All the Data and test results are showed on a 320*240 LCD. ALl the test results could be printed by the micro printer or saved on the storage of the tester. the tester has a good performance on auto protection and anti-disturb. 
  • the transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. GOLD's range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
  • the GBBC-901 is an important tool for determining the mechanical condition of transformers. All ratio tests are performed in one instrument, with only one 3 lead-set connection. the TTRU3 utilizes the latest 7 in. (180 mm) color touch display, as well as an optional printer so results are never lost. this is complimented with remote control which can be operated from a PC, as well as the ability to download results to a USB memory device.
GDBC-901 Transformer Polarity Tester and Terminal Blok Transformer TTR TesterMain functions
  • the voltage ratio measurement of three or singe phase transformer
  • the group vector measurement of three phase transformer.
  • the polarity measurement of single phase transformer or CT/PT
  • Voltage ratio error calculation
  • Voltage ratio range calculation of three phase transformer
  • Current transformer ratio measurement
  • Excitation current measurement in ratio testing
  • Reproduction the AC test voltage from power source to reduce the effects of bad power source
  • Save the test results in the memory internal the tester
  • Print the test results by micro printer
  • Reverse connection detect unit to prevent the high voltage injected to the operate
  • over current protection in test voltage
  • Upload the test results to make word report by RS232 interface

GDBC-901 Transformer Polarity Tester and Terminal Blok Transformer TTR TesterConnection method

IEC791IEC60044 Transformer Polarity Tester and Terminal B Metal CNC cutting machine CNC WoodRouter VCT4030C
GDBC-901 Transformer Polarity Tester and Terminal Blok Transformer TTR TesterTechnique index
  • Ratio measurement range:110000
  • Group measurement:112
  • Phase measurement error:1 degree
  • Ratio measurement error:12000 ± 0.2%   200010000  ± 0.5%
  • Power supply:AC220V ± 10%, 50Hz
  • Size:400350200  mm3     
  • Weight:7kg

GDBC-901 Transformer Polarity Tester and Terminal Blok Transformer TTR TesterGDBC-901 Display

IEC791IEC60044 Transformer Polarity Tester and Terminal B Metal CNC cutting machine CNC WoodRouter VCT4030CIEC791IEC60044 Transformer Polarity Tester and Terminal B Metal CNC cutting machine CNC WoodRouter VCT4030CIEC791IEC60044 Transformer Polarity Tester and Terminal B Metal CNC cutting machine CNC WoodRouter VCT4030C

CHONGQING GOLD

MECHANICAL & ELECTRICAL EQUIPMENT CO., LTD

Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd.  Mainly design and manufacture the oil purifier and electrical testing equipment for more than 11 years.

after several years' development, our products have become high intelligent and wide coverage. and our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;

We have developed sales channels in many countries such as UAE, Saudi Arabia, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.