Product Main

Quick Details

Brand Name: sinolanc
Color: blue
Material: polypropylene
Certificate: CE
size: 20*2mm
Model Number: 10mm
Place of Origin: China (Mainland)
Length: 600mm~8000mm
Width: 1000mm
Distributor pipe: 20x2mm
Capillary pipe: 4.3*0.8mm
Distance between capillaries: 10mm, 20mm, 15mm, 40mm

Specifications

Capillary Tube Mats PLASTER on GYPSUM BOARD

Energy Saving Heating Cooling Capillary Tube Mats Plasterboard Installation

the capillary tube mats are plastered underneath a suspended gypsum board ceiling.

Mat distributor pipes and supply lines are accommodated in the void of the suspended ceiling.

the capillary tube mats, welded together to a hydraulic circuit, are connected to the supply and return lines. The ceiling void can also be used for further installations.

the capillary tube mats run through a slot in the gypsum board panel to the room side and are attached there with stainless steel clips or galvanised staples.Plaster, for example, is applied using the spraying method up to a layer thickness of 15 mm.

Preparation of the Ceiling Structure

1. Install a suspended gypsum board ceiling with sufficient void space to accommodate distributor pipes and supply lines.

2. Ensure the ceiling structure can support the additional weight of the capillary tube mats and the plaster layer.

Positioning the Capillary Tube Mats

1. Mount the supply and return lines for capillary tube mats in the ceiling void, leaving enough space for connections.

2. Secure the two mat distributor pipes of the rolled-up capillary tube mat to the substructure profiles using stainless steel clips or galvanized staples, then connect them to the supply and return lines.

3. Guide the capillary tube mats through a pre-cut slot in the gypsum board panel to the room side.

4. Weld the capillary tube mats together to form a closed hydraulic circuit. Ensure all connections are secure and leak-proof.

System Testing

Perform a leak test at 10 bar, keeping the system filled with water throughout the installation to detect potential damage.

Applying the Plaster Gypsum Board Panels

1. Close the ceiling structure with standard gypsum board panels, fixing them edge to edge

2. Apply a primer coat evenly within 48 hours before plastering to to enhance adhesion.

Securing the Capillary Tube Mats and Plastering

1. Roll out the capillary tube mats and attach them tightly to the underside of the gypsum board over the entire surface and fasten them using stainless steel or galvanized staples.

2. Apply a 10-15 mm plaster layer using professional techniques, ensuring even coverage.

3. Ensure the plastered surface is properly separated from adjacent building components to prevent cracks due to thermal expansion. Allow the plaster to dry and cure properly before proceeding with final ceiling finishes.

Final Inspection and Commissioning

1. Conduct a pressure test to verify the integrity of the hydraulic system.

2. Inspect the installation to ensure proper attachment and finishing.

3. Once confirmed, complete the ceiling construction and proceed with system commissioning.



 

Technical Parameters: 
   


Product Capillary Tube Mat
Material PP-R
Collector pipe size 20*2.0 mm
Capillary tube size 4.3*0.8 mm
Capillary tube spacing 10mm-40mm
Length 600mm - 12,000 mm
Width 480mm, 500mm, 550mm, 1000mm
Weight 290~870g/m2
Water contents 0.16~0.57 l/ m2
Total weight with water 320~1440 g/m2
Connection method Thermal welding
Test pressure before delivery 20 bar max
Operating pressure 3 to 4 bar normal



Model Selection:   


Model: SU 10

Material: PP-R

Main tube: 20*2.0mm

Capillary tube: 4.3*0.8mm

Tube space(A): 10mm

Length(L): 600-12000mm

Width(B): ≤1000mm

Model: SU10Z(fold)

Material: PP-R

Main tube: 20*2.0mm

Capillary tube: 4.3*0.8mm

Tube space(A): 5mm

Length(L): 600-12000mm

Width(B): ≤1000mm

Model: SU 20

Material: PP-R

Main tube: 20*2.0mm

Capillary tube: 4.3*0.8mm

Tube space(A): 20mm

Length(L): 600-12000mm

Width(B): ≤1000mm

Model: SU20Z(fold)

Material: PP-R

Main tube: 20*2.0mm

Capillary tube: 4.3*0.8mm

Tube space(A): 10mm

Length(L): 600-12000mm

Width(B): ≤1000mm

Model: SU 40

Material: PP-R

Main tube: 20*2.0mm

Capillary tube: 4.3*0.8mm

Tube space(A): 40mm

Length(L): 600-12000mm

Width(B): ≤1000mm

Model: SU40Z(fold)

Material: PP-R

Main tube: 20*2.0mm

Capillary tube: 4.3*0.8mm

Tube space(A): 20mm

Length(L): 600-12000mm

Width(B): ≤1000mm



Heating&Cooling System Installation


with the advantage of good Flexibility,the Sinolanc caPillary tube Mats cAn be installed on roof, wall, floor, under the surface decorative materials. They Used in new buildings and refurbishment of various types of buildings.

for cooling purposes, sinolanc capillary tube mats are preferentially installed either in or on the ceilings.

Sinolanc capillary mats can be integrated into walls of various designs and used as wall heating and wall cooling.Underfloor heating systems with capillary tube mats can be used for temperature control in all buildings. They are either integrated into an existing screed or laid directly on an existing floor as a thin-layer underfloor heating system and enable gentle temperature control of floor surfaces.


Professional production and service, strictly test, quality assurance, competitive price. 
Welcome to contact freely. 


Energy Saving Heating Cooling Capillary Tube Mats Plasterboard Installation