| Brand Name: | sinolanc |
|---|---|
| Color: | blue |
| Material: | polypropylene |
| Certificate: | CE |
| size: | 20*2mm |
| Model Number: | 10mm |
| Place of Origin: | China (Mainland) |
| Length: | 600mm~8000mm |
| Width: | 1000mm |
| Distributor pipe: | 20x2mm |
| Capillary pipe: | 4.3*0.8mm |
| Distance between capillaries: | 10mm, 20mm, 15mm, 40mm |
Quick Details
Specifications
Capillary Tube Mats PLASTER on GYPSUM BOARD
the capillary tube mats are plastered underneath a suspended gypsum board ceiling.
Mat distributor pipes and supply lines are accommodated in the void of the suspended ceiling.
the capillary tube mats, welded together to a hydraulic circuit, are connected to the supply and return lines. The ceiling void can also be used for further installations.
the capillary tube mats run through a slot in the gypsum board panel to the room side and are attached there with stainless steel clips or galvanised staples.Plaster, for example, is applied using the spraying method up to a layer thickness of 15 mm.
Preparation of the Ceiling Structure1. Install a suspended gypsum board ceiling with sufficient void space to accommodate distributor pipes and supply lines.
2. Ensure the ceiling structure can support the additional weight of the capillary tube mats and the plaster layer.
Positioning the Capillary Tube Mats1. Mount the supply and return lines for capillary tube mats in the ceiling void, leaving enough space for connections.
2. Secure the two mat distributor pipes of the rolled-up capillary tube mat to the substructure profiles using stainless steel clips or galvanized staples, then connect them to the supply and return lines.
3. Guide the capillary tube mats through a pre-cut slot in the gypsum board panel to the room side.
4. Weld the capillary tube mats together to form a closed hydraulic circuit. Ensure all connections are secure and leak-proof.
System TestingPerform a leak test at 10 bar, keeping the system filled with water throughout the installation to detect potential damage.
Applying the Plaster Gypsum Board Panels1. Close the ceiling structure with standard gypsum board panels, fixing them edge to edge
2. Apply a primer coat evenly within 48 hours before plastering to to enhance adhesion.
Securing the Capillary Tube Mats and Plastering1. Roll out the capillary tube mats and attach them tightly to the underside of the gypsum board over the entire surface and fasten them using stainless steel or galvanized staples.
2. Apply a 10-15 mm plaster layer using professional techniques, ensuring even coverage.
3. Ensure the plastered surface is properly separated from adjacent building components to prevent cracks due to thermal expansion. Allow the plaster to dry and cure properly before proceeding with final ceiling finishes.
Final Inspection and Commissioning1. Conduct a pressure test to verify the integrity of the hydraulic system.
2. Inspect the installation to ensure proper attachment and finishing.
3. Once confirmed, complete the ceiling construction and proceed with system commissioning.
Technical Parameters:
| Product | Capillary Tube Mat |
| Material | PP-R |
| Collector pipe size | 20*2.0 mm |
| Capillary tube size | 4.3*0.8 mm |
| Capillary tube spacing | 10mm-40mm |
| Length | 600mm - 12,000 mm |
| Width | 480mm, 500mm, 550mm, 1000mm |
| Weight | 290~870g/m2 |
| Water contents | 0.16~0.57 l/ m2 |
| Total weight with water | 320~1440 g/m2 |
| Connection method | Thermal welding |
| Test pressure before delivery | 20 bar max |
| Operating pressure | 3 to 4 bar normal |
Model Selection:
Model: SU 10 Material: PP-R Main tube: 20*2.0mm Capillary tube: 4.3*0.8mm Tube space(A): 10mm Length(L): 600-12000mm Width(B): ≤1000mm |
Model: SU10Z(fold) Material: PP-R Main tube: 20*2.0mm Capillary tube: 4.3*0.8mm Tube space(A): 5mm Length(L): 600-12000mm Width(B): ≤1000mm |
Model: SU 20 Material: PP-R Main tube: 20*2.0mm Capillary tube: 4.3*0.8mm Tube space(A): 20mm Length(L): 600-12000mm Width(B): ≤1000mm |
Model: SU20Z(fold) Material: PP-R Main tube: 20*2.0mm Capillary tube: 4.3*0.8mm Tube space(A): 10mm Length(L): 600-12000mm Width(B): ≤1000mm |
Model: SU 40 Material: PP-R Main tube: 20*2.0mm Capillary tube: 4.3*0.8mm Tube space(A): 40mm Length(L): 600-12000mm Width(B): ≤1000mm |
Model: SU40Z(fold) Material: PP-R Main tube: 20*2.0mm Capillary tube: 4.3*0.8mm Tube space(A): 20mm Length(L): 600-12000mm Width(B): ≤1000mm |
Heating&Cooling System Installation
with the advantage of good Flexibility,the Sinolanc caPillary tube Mats cAn be installed on roof, wall, floor, under the surface decorative materials. They Used in new buildings and refurbishment of various types of buildings.
for cooling purposes, sinolanc capillary tube mats are preferentially installed either in or on the ceilings.
Sinolanc capillary mats can be integrated into walls of various designs and used as wall heating and wall cooling.Underfloor heating systems with capillary tube mats can be used for temperature control in all buildings. They are either integrated into an existing screed or laid directly on an existing floor as a thin-layer underfloor heating system and enable gentle temperature control of floor surfaces.
Professional production and service, strictly test, quality assurance, competitive price.
Welcome to contact freely.