| Output: | UART_TTL (3.3V) I2C (3.3V) |
|---|---|
| Theory: | NDIR |
| Usage: | Gas Sensor |
| Brand Name: | Cubic |
| material: | metal |
| Model Number: | CM1107H |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Introduction
CM1107H is base on dual beam platform with measurement range 0-5.00% Vol. It is with idea sensing solution for control and alarm applications. It can be integrated into a wide range of different CO2 alarm applications that are critical in ensuring safety such as cellar, brewery, agriculture facilities, industrial plants, and dry ice storage, code chain, and is also can be used for ventilation system, air purifier, air conditioner, ect.
Features
1.NDIR technology with independent intellectual property.
2.Dual beam detection for superior stability and better accuracy.
3.High accuracy, long term stability, long life (>10years).
4.Temperature calibration within whole measurement range.
5.Signal output UART/I2C.
6.Small size and compact structure, easy to install.
1.Fresh Air System Controller
2.Air Quality Monitor
Specification
| Measurement range |
0-5.00% Vol |
| Resolution |
0.01% Vol |
| Working temperature |
-10°C ~ 50°C |
| Working humidity |
0-95%RH (non-condensing) |
| Storage temperature |
-30°C ~ 70°C |
| Storage humidity |
0-95%RH (non-condensing) |
| Accuracy |
± 0.02% Vol+10% of reading @0°C ~ 50°C, 50±10%RH |
| Sampling frequency |
1s |
| Time to first reading |
≤30s |
| Power supply |
DC 4.5V~5.5V |
| Working current |
<50mA @1s |
| Dimensions |
W33 * H23.4 * D15.2mm(without pin) |
| Weight |
6.3G |
| Signal output |
UART_TTL (3.3V) I2C (3.3V) |
| PWM output |
Output high level minimum duration: 2ms (0% Vol) Output high level maximum duration: 1002ms (5.00% Vol) |
| Life span |
≥10 years |