Output: | UART_TTL |
---|---|
Theory: | NDIR |
Usage: | Gas Sensor |
Brand Name: | Cubic |
material: | metal |
Model Number: | AM1008W |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Introduction
Integrated air quality sensor AM1008W is an ultra-thin indoor air quality sensor integrated particle sensor, NDIR CO2 sensor, temp&humidity sensor and VOC sensor module, with UART and I2C communication protocol. PM1.0, PM2.5 and PM10 can output simultaneously.
OEM/ODM AIR QUALITY SENSOR MODULES CAN BE CUSTOMIZED.
Features
1.4 in 1 sensor module which integrated particle, CO2, VOC and RH&T.
2.PM1.0 PM2.5 and PM10 output simultaneously.
3.Auto-calibration NDIR CO2 sensor.
4.Precise accuracy and robust performance.
5.with voltage regulator design and EMC compliant, strong anti-static ability.
6.Ultra-thin structure.
Applications
1.Air Purifier
2.Fresh Air System
3.Fresh Air System Controller
4.Air Quality Monitor
Specification
1.Air Purifier
2.Fresh Air System
3.Fresh Air System Controller
4.Air Quality Monitor
Specification
Measurement range |
CO2: 0~5000ppm; PM: 0~1000μg/m3; VOC: 0~3level; |
Temperature |
-20℃~70℃; RH:0%~95%RH |
PM accuracy |
PM2.5: 0~35μg/m3, ±5μg/m3 >35μg/m3, ±15% of reading (Condition: 0℃~40℃, 50±10%RH Reference instrument: TSI Dust Source: Cigarette + Arizona A1) |
CO2 accuracy |
±(50ppm+5% of reading) (0~2000ppm, 0~50℃, 50±10%RH) |
Working condition |
-10℃~50℃, 0~95%RH(non-condensing) |
Storage condition |
-30℃~70℃, 0~95% RH(non-condensing) |
Power supply |
DC 5V±0.1V |
Ripple wave |
50mV |
Working current |
<300mA |
Signal output |
UART_TTL |
Dimensions |
W80*H50*D13.6(mm) |