Brand Name: | Cubic-Ruiyi |
---|---|
Weight: | N/A |
Sampling Method: | N/A |
Size: | N/A |
Alarm type: | N/A |
Model Number: | Stand-alone version |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Introduction
the non-road machinery/diesel vehicle exhaust smoke detection system (stand-alone version) is equipped with transmission type smoke meter, display and sampling probe, and optional built-in printer can be used to measure the exhaust smoke of the engine/diesel vehicle; Portable design can realize on-vehicle measurement and real-time grasp of the emission level under actual working conditions.
the smoke detection process is highly automatic and not restricted by site and environmental conditions, greatly shortening the single engine/vehicle detection time, and improving road inspections/sampling inspections/enterprise supervision efficiency.
Meet the requirements of GB 3847-2018 "Diesel vehicle pollutant emission limits and measurement methods (free acceleration method and loading deceleration method"
Meet the requirements of GB 36886-2018 "Non-road mobile diesel machinery exhaust smoke limit and measurement method"
Features
the non-road machinery/diesel vehicle exhaust smoke detection system (stand-alone version) is equipped with transmission type smoke meter, display and sampling probe, and optional built-in printer can be used to measure the exhaust smoke of the engine/diesel vehicle; Portable design can realize on-vehicle measurement and real-time grasp of the emission level under actual working conditions.
the smoke detection process is highly automatic and not restricted by site and environmental conditions, greatly shortening the single engine/vehicle detection time, and improving road inspections/sampling inspections/enterprise supervision efficiency.
Meet the requirements of GB 3847-2018 "Diesel vehicle pollutant emission limits and measurement methods (free acceleration method and loading deceleration method"
Meet the requirements of GB 36886-2018 "Non-road mobile diesel machinery exhaust smoke limit and measurement method"
Features
1.Output testing parameters both opacity N value and light absorption coefficient K value simultaneously
2.Constant temperature control in testing room, not affected by moisture
3.with automatic zeroing function
4.Reserve oil temperature sensor and engine tachometer connection interface
5.Optional built-in printer
Specifications
2.Constant temperature control in testing room, not affected by moisture
3.with automatic zeroing function
4.Reserve oil temperature sensor and engine tachometer connection interface
5.Optional built-in printer
Basis specifications | |
Measurement Indicator/ Measurement Range |
Opacity degree N value: (0~99.99)%; Light absorption coefficient K value:(0~16)m-1 |
Resolution | N:0.1%; K:0.01m-1 |
Error | ±2.0% |
Electrical parameters | |
Communication | RS-232/RS-485 digital output and print interface |
Power Supply | AC220V±10%, 50Hz±1Hz |