JZXC-H142 tyJZXCH142 rectifier slow release relayPE rectifier slow release relay is an important component in interlocking equipment. It is the main equipment to ensure the safe operation of the system. the signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc.. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. the automatic control systems in various fields all use relays.

Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. the reliability of the relay action directly affects the reliability and safety of the signal system.


Product function

JZXC-H142 rectifier slow release relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits.


Product Usage

the JZXC-H142 rectifier slow release relay is used in the signal circuit for the LED signal lighting circuit.


Applicable environment

A) Ambient temperature: -40℃~+60℃;

B) Relative humidity: not more than 90% (temperature +25°C);

C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);

D) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;

E) Working position: horizontal;

F) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.


Product characteristics Mechanical characteristics

Number of contact groups: 4QH;

Identification pin number: 13, 53;

Contact gap: not less than 1.3mm;

Pallet gap: not less than 0.35mm;

Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN;

Contact uniformity error: not more than 0.20mm.


Electrical characteristics

Magnetization value: AC180Ma;

Release value: not less than AC23Ma;

Working value: not less than AC45ma;

Coil resistance: 71 (1±10%) Q2;

the coils are connected in series, connect 1, 4, and use 5 and 6.


Time characteristics

Release time: 0.15 seconds when AC50ma.


Test method

Requirements for testing measuring tools, meters and power supply;

the accuracy of the star for measuring the shape and installation dimensions should not be less than 0.05mm; the accuracy of the feeler gauge should not be less than level 2; the measurement error of the force measurement should not be greater than 2%;

the accuracy of the DC voltmeter and ammeter used for testing should not be less than 0.5, and the accuracy of the AC (50Hz) voltmeter and ammeter should not be less than 1;

the power supply voltage should remain stable, and its fluctuation range should not exceed 5%. the DC power supply should be a DC generator, battery or AC full-wave rectifier power supply (except for special regulations, the ripple factor should not be greater than 5%). the waveform of the AC power supply should be a sine wave with a frequency of 50 Hz.


Product electrical life

the relay contacts are connected to DC24V1A resistive load; its electrical life is 1106 times.


Product structure

the electromagnetic system of the rectifier relay is the same as that of the infinite relay. Only the magnetic circuit structure parameters are different. It is mainly to install a half-wave or full-wave rectifier circuit composed of diodes above the contact group.


Insulation withstand voltage

under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ.

under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.


Installation Precautions

(1) When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and that the socket identification pin is in the correct position and should not be missing.

(2) Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging.

(3) When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket.


Faults and troubleshooting methods

Relay contact has no output

the analysis and elimination methods of the relay contact without output are as follows:

(1) Make sure that the relay and socket should be reliably plugged in;

(2) Check that the relay should not be mechanically blocked. If a foreign object in the relay blocks the armature, the armature cannot work reliably (forward rotation) or release (reverse rotation), and the contacts cannot be reliably contacted;

(3) Check that there should be no foreign matter between the contacts, there is foreign matter between the contacts, and the contacts cannot be reliably contacted;

(4) Check that the contact resistance of the relay contact should not be too large. the relay does not work or the relay with a pole cannot be reversed in the forward direction

the relay does not work or the relay with a pole cannot be reversed in the forward direction. the analysis and troubleshooting methods are as follows:

(1) Make sure that the relay and socket should be reliably plugged in;

(2) Check that the input voltage or current of the relay coil should be the rated value or the system circuit adjustment value.

Method: Use a multimeter to check the voltage relay coil input terminal voltage on the socket should meet the output voltage of the power supply screen; use a multimeter to check the voltage drop of the current relay coil input terminal on the socket should meet the voltage drop requirements of the system circuit for reliable operation of the relay; otherwise, system error;

(3) If the above two items are normal, it can be determined that the relay is faulty and the relay should be replaced;

(4) the relay coil is short-circuited or disconnected, the relay cannot work reliably or has a pole relay;

(5) the diode of the rectifier relay is impacted or short-circuited, and the rectifier relay cannot work reliably;

(6) Check that the relay should not be mechanically blocked. If the foreign matter in the relay blocks the iron, the relay cannot work reliably or reverse polarity.


Maintenance

Daily maintenance and maintenance

A) Keep the relay and socket clean;

B) Observe whether the relay operation status is normal;

C) the relay should be replaced in time for abnormal operating conditions and serious contact burnout.


Regular maintenance

in the electrical life and life management cycle of the relay, the maintenance cycle of the infinite relay and rectifier relay should be five years; the maintenance cycle of the stepless enhanced contact relay, the poled relay and the biased pole relay should be three years; the maintenance cycle of the stepped enhanced contact relay the period should be one year; appearance inspection and performance inspection should be carried out after overhaul.


Packaging, transportation, storage

(1) Packaging

the outer packaging of the relay adopts a carton structure, and the carton is equipped with a foam box to ensure that the relay will not damage the instruction manual of the relay in each packaging box during the normal transportation process.

(2) Precautions for transportation

during storage and transportation, the relay should not be subjected to strong vibrations, collisions, or rain or snow.

(3) Storage conditions, storage period and precautions

the relay should be stored in a well-ventilated warehouse with a temperature of -25C, +40℃, a relative humidity of less than 80%, and no acid, alkali or other harmful gases around. It should not be exposed to rain or snow during storage. The storage period is one year, and the storage period should be inspected or repaired before use.


after-sales service

from the date of delivery, the warranty period of infinite relays, rectifier relays (the warranty period of electronic components is one year), polarized relays and biased pole relays is 1 year, and the warranty period of infinitely enhanced contact relays and polarized enhanced contact relays Provide free maintenance services for the company during the one-year warranty period; for relays that exceed the warranty period, the company will provide life-long technical support based on the actual situation and the cost of the maintenance items, and create a way for users to master the use and maintenance methods of the relay.

(1) the relays that have been unsealed due to poor quality or damage due to transportation, storage, improper use, etc., are not covered by the company's warranty;

(2) If the user violates the technical requirements of this manual or fails to perform normal maintenance according to the maintenance manual during installation and use, the company will not bear any responsibility for the damage;

(3) during the company's warranty period, if our company's products and parts are unpacked without the company's authorization, the company will not be responsible for any quality problems arising therefrom;

(4) Non-our company's parts and components are assembled on the company's products without the company's consent and cause product quality problems. the company does not bear any responsibility for this.