Product Main

Quick Details

Brand Name: Konsung
size: 33cm*33cm*24cm
Feature: Health Care
Physiotherapy equipment: therapy Asistant
material: ABS+PC Fireproof Materials
Model Number: Aurora
Place of Origin: China (Mainland)
Basic Parameters: ECG, NIBP, SpO2, Resp, Temp, Pr/Hr
Option Parameters :: Etco2, 2IBP, 12-LED ECG

Specifications

CE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six Parameters
    CE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six Parameters

CE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six ParametersCE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six ParametersCE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six Parameters
Product Parameters
 
Standard configuration
Screen
Display Type 12.1" color TFT LCD
Resolution 800600 pixels
Waveforms up to 7
ECG
Input 3/5 wire ECG cable
Lead section I II III aVR, aVL, aVF, V
Gain selection *0.25, *0.5, *1, *1.2
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Heart rate range 15-30bpm
Calibration ±1mv
Accuracy ±1bpm or ±1% (select the bigger data)
NIBP
Test method Oscillometer
Philosophy Adult, Pediatric and Neonate
Measurement type Systolic Diastolic Mean
Measurement parameter Automatic, Continuous measurement
Measurement method Manual MmHg or ±2%
SPO2
Display Type Waveform, Data
Measurement range 0-100%
Accuracy ±3% (between 70%-100%)
Pulse rate range 20-300bpm
Accuracy ±1bpm or ±2% (select the bigger data)
Resolution 1bpm
2-Temperature (Rectal & Surface)
Number of channels 2 channels
Measurement range 0-50C
Accuracy ±0.2C
Display T1, T2, T
Unit  C/F selection
Refresh cycle 1s-2s
Respiration (Impedance & Nasal Tube)
Measurement type 0-150rpm
Accuracy ±1bm or ±5%, select the bigger data
Resolution 1rpm
Optional configuration
EtCO2-Plug & Play
Measurement type Side stream
Measurement range 0-10.0%; 0-76mmHg
Accuracy <5.0%, ±0.28kPa; ±2mmHg
>5.0%, ±10%
2-IBP (optional)
Measurement range 10~300mmHg
Number of channels 1 or 2 channels
Accuracy ±1mmHg or ±2%, select bigger data
Pressure tag ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP
12 leads ECG (optional)
Input 3/5/10 wires ECG cable
Lead section I, II, III aVR, aVL, aVF, V(V1-V6)
Heart rate range 15-380bpm
Calibration ±1mv

CE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six ParametersCE Approved China Medical Portable MultiLanguage Bedside Patient Monitor with Six Parameters