Brand Name: | MTKY |
---|---|
Accuracy: | 3% |
Material: | ABS |
Measuring range: | 0~200,000Lx |
display color: | Blue |
Model Number: | GM1030 |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Material: ABS
Measurement Function: Illuminance and Temperature, Illuminance Difference, Illuminance Maximum and Illuminance Minimum
Illuminance Probe: Silicon Photodiode
Temperature Probe: NTC Thermistor
Illuminance Range: Total Range: 0~200,000Lx
Divided into 4 Levels:
1: 0~199.9Lx Minimum Resolution: 0.1Lx
10: 20.0x10~199.9x10Lx Minimum Resolution: 1Lx
100: 20.0x100~199.9x100Lx Minimum Resolution: 10Lx
1000: 20.0x1000~199.9x1000Lx Minimum Resolution: 100Lx
Illumination Accuracy:
1: ±3%rdg+5dgts
10: ±3%rdg+10dgts
100: ±4%rdg+10dgts
1000: ±4%rdg+10dgts
Temperature Range: -20 ~ 50C (-4~122F)
Temperature Accuracy: ±1.0C
Repeatability: ±2%
Refreshing Rate: 2 Times/Sec
Illumination and Temperature Unit: Lx (lx)/C (degrees Celsius) Lx (lx)/F (degrees Fahrenheit) FC (foot candles)/C (degrees Celsius) FC (foot candles)/F (Fahrenheit)
Illumination Data Storage: maximum storage of 2000 (automatic storage) maximum storage of 60 (manual storage)
Power Supply: 3 x 1.5V AAA Dry Battery (Battery Not Included)
how to Use:
1: Open the illuminance meter receiving cover
2: Install the battery 3 x 1.5V AAA (this product does not include)
3: Press the power button and move the receiver as close as possible to the measured light source (the gear is automatically adjusted according to the strength of the light source)
Measurement Function: Illuminance and Temperature, Illuminance Difference, Illuminance Maximum and Illuminance Minimum
Illuminance Probe: Silicon Photodiode
Temperature Probe: NTC Thermistor
Illuminance Range: Total Range: 0~200,000Lx
Divided into 4 Levels:
1: 0~199.9Lx Minimum Resolution: 0.1Lx
10: 20.0x10~199.9x10Lx Minimum Resolution: 1Lx
100: 20.0x100~199.9x100Lx Minimum Resolution: 10Lx
1000: 20.0x1000~199.9x1000Lx Minimum Resolution: 100Lx
Illumination Accuracy:
1: ±3%rdg+5dgts
10: ±3%rdg+10dgts
100: ±4%rdg+10dgts
1000: ±4%rdg+10dgts
Temperature Range: -20 ~ 50C (-4~122F)
Temperature Accuracy: ±1.0C
Repeatability: ±2%
Refreshing Rate: 2 Times/Sec
Illumination and Temperature Unit: Lx (lx)/C (degrees Celsius) Lx (lx)/F (degrees Fahrenheit) FC (foot candles)/C (degrees Celsius) FC (foot candles)/F (Fahrenheit)
Illumination Data Storage: maximum storage of 2000 (automatic storage) maximum storage of 60 (manual storage)
Power Supply: 3 x 1.5V AAA Dry Battery (Battery Not Included)
how to Use:
1: Open the illuminance meter receiving cover
2: Install the battery 3 x 1.5V AAA (this product does not include)
3: Press the power button and move the receiver as close as possible to the measured light source (the gear is automatically adjusted according to the strength of the light source)