the following example is for you reference.
Main Advantages:
Technical details:
Fault phenomenon |
Reason |
Resolution method |
1. the motor can't start |
1. the fuse is blown 2. the control circuit is faulty |
1. Replace the fuse 2. Inspection control circuit |
2.the crusher is seriously vibrating |
1. Hammer wear is uneven 2. Symmetrical hammer weight deviation is large 3. Overload operation |
1. Adjust or replace 2. Balance matching 3. Reduce the amount of feed |
3.the crusher sounds abnormal |
1. Iron, stone into the crusher 2. the parts inside the machine are damaged or fall off |
1. Shutdown to do clear 2. Replace the damaged parts |
4.Finished product process |
1. the sieve is seriously worn 2. the sieve is not settled well |
1.Replace the sieve 2. Re-install |
5. Production Reduced |
1. Material moisture is too high 2. the hammer is worn out |
1. Drying materials 2. Turn the head or replace the hammer |
6. the suction nozzle can't suck feed. |
1. Suction point blocked 2. Fan blades are seriously worn 3. Poor exhaust 4. the voltage is too low |
1. Clear the blockage 2. Change the blade 3. Remove the dust bag 4. Identify the cause |
7. Crushing motor heating |
1. Feeding speed is too fast 2. High material humidity 3. Low voltage |
1. Adjust the feeding speed 2. Replacement of materials 3. Check the line |
8. the mixer can't pull |
1. Motor belt is loose 2. Motor reversal 3. Line faulty |
1. Tightening the belt 2. Adjust the thread head 3. Check the line |
Our Factory:
Certificates:
Our Service:
FAQ: