Usage: | Auto Testing Machine |
---|---|
Power: | Electronic |
Brand Name: | tianqi |
Warranty: | one year |
weight: | 200kg |
Model Number: | TD130-1 |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
I. Overview of TD130-1 variable head penetration tester
TD130-1 variable head penetration test instrument is developed by Hebei Tianqi Xingzi Testing Equipment Co., LTD according to T0130-2007 "Constant Head Penetration Test" in "People's Republic of China Industry Standard JTGE40-2007".
TD130-1 variable head permeability tester is suitable for fine grained soil. the distilled water used in this test should be degassed by pumping or boiling before the test. the water temperature during the test should be 3 ~ 4℃ higher than room temperature. It is mainly composed of upper cover, base, sleeve, ring knife, permeable stone, screw and so on. the instrument is changed into the middle spiral rod in the pressing way, and the deficiencies of the same type of instrument are improved to make the operation more convenient.
Ii. Technical parameters of TD130-1 variable head Penetration tester
1. Sample size: φ61.8mmX40mm (30 square cm)
2. Instrument dimensions:φ118 (except the nozzle) X172X190mm,
3. the net weight of the instrument is about 3.5kg.
Iii. Operation procedure of TD130-1 variable head penetration test instrument
1. Prepare the sample by referring to the geotechnical test procedure SD128-012-84 of the Ministry of Hydropower of variable Head Osmosis Instrument, or JTJ051-93, Highway Geotechnical Test Procedure T013-93
2. Put the seepage stone and sealing ring into the base, coat the inner wall of the sleeve with a layer of petroleum jelly, put the soil sample ring knife, and scrape the excess petroleum jelly on the base.
3, put on the sealing ring, permeable stone, the cover, tighten the screw, no water leakage.
4, the inlet pipe and water supply device connected, and water exhaust flat instrument,
5. under the action of no more than 200cm water head, let it stand for a certain time, and then start the measurement after water escapes from the outlet pipe.
6. during the test, after the head tube is flushed to the required height, the stopwatch is started with the pipe clamp, and the starting head h1 is recorded at the same time. after time t, the recording is terminated, which is the same as the water temperature when the test is terminated.
IV. Calculation formula of TD130-1 variable head penetration tester
(variable head) permeability coefficient is calculated according to the formula; KT = 2.3 the log
Where: a---- cross-sectional area of variable head pipe, square centimeters
L---- Penetration diameter, equal to the sample height. Cm
H1-- Water head at the beginning, centimeters
H2-- Water head at termination, cm
V. Technical requirements of TD130-1 variable Head Penetration tester:
1. the variable head penetrator should have a nameplate, which should indicate the product name, model specification, number, manufacturer name and factory date.
2. the surface of the instrument castings should have no obvious holes, the permeable coating should be smooth, smooth and uniform with the same tone, and there should be no defects affecting the appearance quality such as peeling, scratches and scratches.
3. the top cover, the bottom cover and the sleeve shall be made of corrosion-resistant and wear-resistant metal materials that are not easy to deform, and the surface roughness of the surface and inner wall is RM6.3
4. both ends of the permeable plate should be flat, and its permeability coefficient should not be less than 1X10 cubic centimeters.
5. Ring cutter shall comply with the provisions of SD191-86 (cutting ring cutter).
6. after the instrument is assembled and tightened, the ring knife should not be suspended and not be damaged under pressure and should not leak under 100KPa air pressure.
7. the water force tube shall meet the requirements of Class B burette 1-100ml.
Vi. Notes for TD130-1 Variable Head Penetration Tester:
1. the rubber tube at the top cover outlet pipe is not easy to reach the root, so more than 6mm should be set aside to prevent compression with the sleeve.
2, each time after use should be wiped dry, sealing ring should be wiped with talcum powder preservation.
3. Soil cutting ring knife should be properly kept to prevent cutting edge damage
TD130-1 variable head penetration test instrument is developed by Hebei Tianqi Xingzi Testing Equipment Co., LTD according to T0130-2007 "Constant Head Penetration Test" in "People's Republic of China Industry Standard JTGE40-2007".
TD130-1 variable head permeability tester is suitable for fine grained soil. the distilled water used in this test should be degassed by pumping or boiling before the test. the water temperature during the test should be 3 ~ 4℃ higher than room temperature. It is mainly composed of upper cover, base, sleeve, ring knife, permeable stone, screw and so on. the instrument is changed into the middle spiral rod in the pressing way, and the deficiencies of the same type of instrument are improved to make the operation more convenient.
Ii. Technical parameters of TD130-1 variable head Penetration tester
1. Sample size: φ61.8mmX40mm (30 square cm)
2. Instrument dimensions:φ118 (except the nozzle) X172X190mm,
3. the net weight of the instrument is about 3.5kg.
Iii. Operation procedure of TD130-1 variable head penetration test instrument
1. Prepare the sample by referring to the geotechnical test procedure SD128-012-84 of the Ministry of Hydropower of variable Head Osmosis Instrument, or JTJ051-93, Highway Geotechnical Test Procedure T013-93
2. Put the seepage stone and sealing ring into the base, coat the inner wall of the sleeve with a layer of petroleum jelly, put the soil sample ring knife, and scrape the excess petroleum jelly on the base.
3, put on the sealing ring, permeable stone, the cover, tighten the screw, no water leakage.
4, the inlet pipe and water supply device connected, and water exhaust flat instrument,
5. under the action of no more than 200cm water head, let it stand for a certain time, and then start the measurement after water escapes from the outlet pipe.
6. during the test, after the head tube is flushed to the required height, the stopwatch is started with the pipe clamp, and the starting head h1 is recorded at the same time. after time t, the recording is terminated, which is the same as the water temperature when the test is terminated.
IV. Calculation formula of TD130-1 variable head penetration tester
(variable head) permeability coefficient is calculated according to the formula; KT = 2.3 the log
Where: a---- cross-sectional area of variable head pipe, square centimeters
L---- Penetration diameter, equal to the sample height. Cm
H1-- Water head at the beginning, centimeters
H2-- Water head at termination, cm
V. Technical requirements of TD130-1 variable Head Penetration tester:
1. the variable head penetrator should have a nameplate, which should indicate the product name, model specification, number, manufacturer name and factory date.
2. the surface of the instrument castings should have no obvious holes, the permeable coating should be smooth, smooth and uniform with the same tone, and there should be no defects affecting the appearance quality such as peeling, scratches and scratches.
3. the top cover, the bottom cover and the sleeve shall be made of corrosion-resistant and wear-resistant metal materials that are not easy to deform, and the surface roughness of the surface and inner wall is RM6.3
4. both ends of the permeable plate should be flat, and its permeability coefficient should not be less than 1X10 cubic centimeters.
5. Ring cutter shall comply with the provisions of SD191-86 (cutting ring cutter).
6. after the instrument is assembled and tightened, the ring knife should not be suspended and not be damaged under pressure and should not leak under 100KPa air pressure.
7. the water force tube shall meet the requirements of Class B burette 1-100ml.
Vi. Notes for TD130-1 Variable Head Penetration Tester:
1. the rubber tube at the top cover outlet pipe is not easy to reach the root, so more than 6mm should be set aside to prevent compression with the sleeve.
2, each time after use should be wiped dry, sealing ring should be wiped with talcum powder preservation.
3. Soil cutting ring knife should be properly kept to prevent cutting edge damage