Product Main

Quick Details

Brand Name: ESDMAN
color: -
Theory: -
Resolution: -
Size: -
Model Number: HG-03
Place of Origin: China (Mainland)

Specifications

Safety:
  • Do not disassemble the item without permission.
  • It is prohibited using under the dangerous environment (such as flammable and explosive)
  • Do not use in place with plenty of oil or water, high temp and high humidity, especially the place with dew.
  • the air nozzle must use compressed air, operating it without compressed air may cause product damage and other accidents.
  • It's forbidden to touch the discharge emitter when it is power on.
  • Don't operate it by wet hand, otherwise it may cause electronic shock or other failure.
  • Don't let fingers, iron wires and tools etc metal object close to discharge emitter.
  • Please check power supply specification before connecting power adapter and use supplied power adapter.
  • the supplied power adapter is special for HG-03 air gun, please do not use it for other purposes.
  • It is necessary to use an air pipe with suitable pressure resistance (outer diameter 8mm)
  • Please do not use the equipment in confined space because it will produce ozone (below 0.05ppm)
Industry Standard and System Certificate:
  • It passed ISO 9001:2015 (certification code:18ACM6508Q) quality management system certification
  • It passed CE / EN 55014-2:2015 & EN 61326-1; 2013 certification
  • It passed FCC / 47 CFR FCC PART 15 SUBPART B; 2017 certification
  • Comply with limit request of ANSI/ESD S20.20 on ionizer doing auditing test and compliance verification test
  • Comply with request of ANSI/ESD STM 3.1 on ionizer doing auditing test
  • Comply with request of ANSI/ESD SP 3.3 on ionizer doing periodic compliance verification test
  • Comply with limit request of IEC 61340-5-1 on ionizer doing auditing test and compliance verification test
  • Comply with limit request of JESD 625-B on ionizer doing verification test
  • Comply with limit request of GJB3007A-2009 on ionizer doing verification test
  • Comply with ISO14644-1 Class 4 clean request
  • It has been widely used in Europe, America and Southeast Asia
Product Overview:
  • 0.01um accuracy filter is inside the gun body and it has a light touch switch and LED indicator.
  • Lightweight gun body convenient for moving and operation, which designed according to ergonomics. 
  • the controller uses solenoid valve control way to reduce operator's fatigue. and it can also use foot tap switch control way to completely relax hands.
  • No high voltage wires between gun body and controller, which makes the operator more safety.
  • It uses high frequency AC discharge technology, the discharge frequency is 68KHz, the ion density is high, the ion balance can be controlled within 0 ± 15V, and decay time within 0.5Ionizing BlowOff Gun HG03 ESDMAN
Specification:
Ionizing BlowOff Gun HG03 ESDMAN
Product Detail Images and Classify Introduction:
Ionizing BlowOff Gun HG03 ESDMAN

Notes:
  • Only used for eliminating static control and dust, other application is forbidden.
  • Please do not use it in places with strong magnetic fields and strong electric fields
  • Please eliminate static in places the charged object can't touch grounded metal.
Please enter clean and dry air. If water or oil is included,Which may reduce performance and environment pollutionIonizing BlowOff Gun HG03 ESDMAN

Installation and Use Method:
Ionizing Blowoff Gun HG03 ESDMAN

  • Please choose places with AC110V/220V or DC24 power supply and compressed air.
  • Please connect DC24V output into controller power input.
  • Please connect 100-240V power to grounded socket.
  • Connect controller air input into compressed air hose, pressure is 0.1-0.7mpa, and it is Recommended to use 0.5MPa at most.
  • Please install the dust filter (0.3u) and filter for oil and water in the air outlet of the Compressor. the input air temperature range please control between 5 to 40°C.
  • Connect the air hose connector with the air filter outlet correctly.
  • Connect filter air inlet and power adapter into controller.
  • Fix controller and bracket by M3 flat head screw and use M3 flat head screw to fix the bracket in proper position.Installation metal clip from the controller need to be grounded with ground.
  • Open controller switch, green LED will be on when controller is normal.
  • Green LED will lamp when pull the trigger, air outlet will export air ion; however if green LED Will not lamp when pull the trigger, it means air gun has malfunction, it needs to be repaired.
  • Blow air to a charged equipment or a dusty object.
  • Release trigger after finished eliminating static or dust, air and power adapter will stop soon.
  • Place the air gun to a proper position when stop using.
Notes
  • Precision components are included. It is strictly forbidden to place it on the platform with Severe vibration. It is strictly forbidden to drop or knock hard to cause product damage or Failure.
  • It is forbidden to pull the air hose and the power cord with excessive force to avoid damaging the gun body controller and the power cord of the air hoseIonizing BlowOff Gun HG03 ESDMAN

Test Method:
Test offset voltage and decay time.
       a. Test before delivery
  • Test Equipment:ME-288B Charge Plate Monitor
  • Test equipment and be tested air gun both need to be grounded well
  • Air gun outlet is aligned with the CPM center and test according to distance 15cm
Ionizing BlowOff Gun HG03 ESDMAN
       b. on site test method
  • Charge plate monitor need to be placed at the actual operating of ESD sensitive components
  • Detailed test method should be referenced as different equipment's user manual
Performance:
  • Operating Voltage: DC24V
  • Testing Voltage: ± 1000V - ± 100V
  • Temperature: 23°C ± 3°C
  • Hum: 50% ± 5%
  • Measurement Method: measure with 20PF, 150mm electrostatic elimination monitor
  • from ± 1000V - ± 100V decay time when air pressure is 0.2Mpa
         Different environments show different test results. the above mentioned is the reference data. 
         Please test according to the actual environmentIonizing BlowOff Gun HG03 ESDMAN
Maintenance:
        Emitter will be contaminated after long-time use. the dust adsorption will reduce eliminating statics or cause other malfunction once continue to use the air gun without maintenance. The emitter must be cleaned regularly (recommend one time every two weeks)
       Notes
  • Do not remove the emitter except replace emitter
  • Pull out the power supply before cleaning
  • Turn off the compressed air outlet switch before cleaning
  • Do not use solvents or cleaning lotion, otherwise it will cause product cracks, electric shock or other malfunction
  • Do not clean by water, or it may cause electronic shock
  • Only professional serviceman can repair or amend this product, otherwise it will cause malfunction or electronic shock risk.
        Clean the shell
          Please use a soft clean cloth to wipe the stain on the product, do not use alcohol or thinner Solution cleaning.Ionizing BlowOff Gun HG03 ESDMAN         
Replace filter
         the replacement cycle of filter almost depends on the application environment, different application environment has different replacement cycle.
  • Press the quick connection switch 1 of the filter inlet to separate the filter and gun power connector from the controller.
  • Then press the quick connection switch 2 at the end of the hose to separate the old filter inlet from quick interface.
  • Install the new filter outlet into the quick interface 2 at the end of the air hose.
  • Install the new filter inlet and power supply of the air gun into the controller, press the filter inlet quick connection switch 1, and then after you hear a click, the replacement is completed.
  • Before operation, please check if the filter and the socket of air gun power supply is correctly Connected to the controller and insure it would not be breaking away.    Ionizing BlowOff Gun HG03 ESDMAN
Troubleshooting Guide:Ionizing BlowOff Gun HG03 ESDMAN

Storage:
         Do not store this product at the below mentioned places, otherwise it will cause malfunction
  • Strong shock or impact place
  • Places with more chemicals, oil and water 
  • Temperature has big change place
  • Places with strong electromagnetic field
  • Places with more smoke, fog and dust
  • Places with dust or combustible solvent
  • High Temp and high humidity place
Warranty:
ESDMAN products have passed strict factory case of failure,please contact our ESDMAN team and provides details of the failure.
Warranty
  • 12 months from the date when products arrived at the buyer's place.
Coverage
  • this product is inspected by ESDMAN QC, when it is in normal use within the warranty period, if it is damaged or fails due to poor design and manufacturing, free maintenance could be provided.
Out of coverage
  • Emitter belongs to the loss part and are not covered by warranty.
  • Damage, breakage or failure due to abnormal use.
  • Failure caused by modification or disassemble of maintenance not from ESDMAN.
  • Failure caused by fire, natural disaster, flood, earthquake and other natural irresistible factors.
  • Failure caused by abnormal voltage etc external factors.
Package Include:
Part Included List
Ionizing BlowOff Gun HG03 ESDMAN