Our anesthetic gas detector can simultaneously measure the concentration waveform and data of CO2, N2O,Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane and desflurane. The user can manually select the type of anesthetic gas.
Types of Detectors
Anesthesia Multi-Gas Detector AneSure?-M
Mainstream Anesthesia Multi-Gas Module, simultaneously measure the concentration waveform and data of carbon dioxide, nitrous oxide and anesthetic gas, as well as respiratory rate.
Anesthesia Multi-gas Detector AneSure?-S
Side stream Anesthesia Multi-Gas sensor, can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gas, as well as respiratory rate.
Features of Anesthesia Multi-gas Detector/Module
1.Compatible with a variety of protocols, so that the products can be quickly upgraded and assembled.
2. Plug and play, the host does not need internal circuit, just a serial port. Can measure data within 4 seconds after power on. Suitable for adults, children and newborns.
3. Can also be used in heavy humidity environment for a long time, reducing the cost of use.
4. Automatic pressure compensation. There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
5. High-precision. Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio, to ensure the measurement accuracy for temperature range of - 5-50 °C and in the range of 0 - 20%.
Benefits of Anesthesia Multi-gas Detector/Module
Mainstream and sidestream modes
Compatible with multiple protocols
Plug and Play
Flexible upgrade
Provide you with a one-stop solution for your clinical needs
Excellent performance and reasonable price
Specifications of Anesthesia Multi-gas Detector/Module
Temperature |
-5~50℃ |
Relative humidity |
10-90%(Non-condensing) |
Atmospheric pressure |
55-115kpa |
Power consumption |
150ma |
Port and protocol |
RS-232/ Standard E-8-1,38.4 kBaud,10 ms data interval (KM) or Customized according to customers' requirements |
Co2 Measuring Range |
0~150mmHg |
Accuracy |
0~40mmHg, inaccuracy≤± 2mmHg; 41~70mmHg, inaccuracy≤±5% of Reading; 70~100mmHg, inaccuracy≤± 8% of Reading; 101~150mmHg, inaccuracy≤±10% of Reading; |
NO |
Measuring range 0~100% Inaccuracy±(2vol%+ 2% of Reading) HAL, ENF, ISO |
HAL, ENF, ISO |
Measuring range 0-12% Inaccuracy for 0~8%, ±(0,2 vol% + 5% of Reading) for 8~12% Unspecified |
SEV |
Measuring range 0~15% Inaccuracy for 0~10%,±(0,2 vol%+5% of reading) for 10~15% unspecified |
DES |
Measuring range 0~25%; Inaccuracy for 0~18%,±(0,2 vol%+5% of reading) for 18~25% unspecified |
Respiration Rate Range |
2~150 t/min |
Inaccuracy |
the bigger value of ±1% or 1t/min |
If you want to know more details of, please visit our website.
Now the price of Machine is reasonable, if you have needs, please leave us a message.