Product Main

Quick Details

Brand Name: ESDMAN
color: -
Theory: -
Resolution: -
Size: -
Model Number: HN-04
Place of Origin: China (Mainland)

Specifications

Warning:
  • Do not use the product in watering place, the product should avoid water. Or else it will probably cause personnel electric shock or even fire.
  • This product is not an explosion-proof product. It is strictly prohibited to use in hazardous environment (such as inflammable and explosive environment).
  • It has high voltage device and should avoid water or oil, high temperature or high humidity, especially prohibitted in high humidity and condensation.
  • Please do not disassemble this product without authorization, it will cause product malfunction, personnel electric shock or even fire, and no warranty. If you need maintenance, please contact us directly. 
  • Please turn off power supply before maintenance. Or else it will cause to personnel electric shock or even fire.
  • Ionizing Gun must use compressed air. It is strictly prohibited to use it in no compressed air environment as it may cause product malfunction or other accidents.
Caution:
  • Do not touch the discharge needle under power-on conditions, otherwise it may cause malfunction or electric shock accident.
  • Please place the product to the specified position when leaving the working area. 
  • Do not put fingers or metal objects (such as wires and tools) close to the discharge needle, otherwise it will cause a malfunction.
  • Please check power supply specification before connecting it. Use the unusual or irregular power supply will cause product malfunction or other accidents.
  • Please do not do operation with wet hands, it may cause personnel electric shock or product malfunction.
  • Please do not use it except for static elimination and dust removal. 
  • It is strictly required to use a air hose with pressure resistance. 
  • A trachea that has no or poor pressure resistance may have a ruptured or leaking airway.
  • The emitter needle is very sharp. Please pay attention not to prick the finger. 
  • Please do not use it in confined spaces. Ionizing gun will generate ozone. (0.05 ppm or less). 
  • If it has ozone smells when multiple ionizing guns are working, please ventilate immediately. 
Industry standard and system:
  • Our company's products have passed the ISO 9001:2015 (certification number: 18ACM6508Q) quality management system certification, and we strictly make production according to the requirements of the quality certification system. And in accordance with 6.2.3.1 of ANSI/ESD S20.20, when electrostatically insulating objects or isolated semiconductors generate static electricity, ionization techniques should be used to generate positive and negative ions to neutralize static electricity.
  • The ionization neutralization technology is effectiveless for objects with large capacitors, such as human bodies, but it should be adopted in cases where grounding is impossible. According to IEC 61340-5-2:1, ionization neutralization techniques should not be the first choice for conducting objects and human bodies. It not only passed CE (EN 55014-2:2015) , FCC (FCC PART15 SUBPART B:2017) certification. It is also well approved and used by many giant customer at European, American and Southeast Asia.
Product Introduction:
  • A specialized inside electric high voltage transformer, compact size, light body. Low power consumption which helps enviromental protection. No HV connecting cord keep it safer and more convenient to use.
  • Automatic ion balance system, the ion balance can be ± 15v.
  • Removable power supply and emitter needle eases cleaning and parts replacement. No need to adjust the blow angle again after maintance or replacement.
  • Built-in power indicator, high voltage operation indicator, and high-voltage abnormal warning indicator and a cleaning indicator. 
  • Remote alarm signal output (RS485/relay switch signal, optional). 
  • The RS485 network can be connected to the computer to monitor the static elimination of ESD sensitive areas.
  • Special alloy emitter needles are designed for long term use without wear and can be used in the clean room.
  • Variety of nozzle tips can be selected for different applications.
  • Can be in Daisy Chain design (power supply purchased separately)
  • CE and FCC Compliant
Package Contents:
Check the package contents firstly after unpacking
  • Air Nozzle *1
  • User Manual *1
  • Power cord *1
  • Ground cord *1
  • Mounting bracket *1
Optional accessories for strengthening other functions
Emitter needle; Different kind of power supply adapter; High voltage module; Insulating liner. Can be customized with various specifications of nozzles (standard straight air nozzle, long nozzle, 60° annular diffusion nozzle, 90° annular diffusion nozzle, Bender tube straight air nozzle, Bender tube 60° diffusion nozzle, Bender tube 90° diffusion nozzle, hose nozzle, rod nozzle straight type, rod type nozzle ring type)
Product Detail Images and Classify:Ionizing Air NozzleHN04 ESDMANAppearance Pictures:Ionizing Air NozzleHN04 ESDMANHow to Use:
  • Only used for eliminating static control and dust, other application is forbidden.
  • Please do not use it in places with strong magnetic fields and strong electric fields
  • Please eliminate static in places where the charged object can not be grounded.
  • Please stop using if there is an abnormity 
  • Please enter clean and dry air (CDA).
  • If the air include water or oil, which may reduce performance and Environment pollution
  • Please make sure that the air input hose is connected well.
  • Please connect DC24V output into console power input.
  • Please connect 100-240V power to grounded socket.
  • Please adjust the pressure regulator of the air compressor to 0.01-0.7Mpa. (Maximum suggested: 0.5Mpa)
  • Please connect the nozzle tail connector correctly to the 6mm compressed air pipe.
  • Blow air to a charged equipment or a dusty object.
  • Do not use in no compressed air environment.
  • It is strictly prohibited to place the product on the platforms which is hard shaking as it has precision device inside. Do not drop the product down or hit it hard, otherwise it may cause malfunction or product damage.
Specifications:Ionizing Air NozzleHN04 ESDMANTest Procedure and Test:
Air nozzle is one of the important tools and equipment to eliminate static electricity in the production process, as the emitter needle will be affected by the environment and dust after long-term use, the positive and negative balance voltage will be offset, in order to ensure the normal use of the Nozzle Ionizer, it is necessary to use the electrostatic field meter to regularly test its performance, mainly to test the ion balance and decay time two performance parameters. 
Test equipment and usage 
a. Equipment name: ME-288B electrostatic field meter 
b. Instrument accessories: CPM, charge plate monitor, grounding wire, 100v-240v wire. 
c. The test instrument shall be grounded well, and the air nozzle shall be grounded correctly. 
Both test instrument and air nozzle should be grounded properly. 
d. The ion outlet of the air nozzle is aligned with the plate tester, and is tested according to different air pressure. 
e. The specific test method, subject to the different test instrument specifications. 
f. Different environments show different test results. The above mentioned is the reference data. 
Please test according to the actual environment. Ionizing Air NozzleHN04 ESDMAN
Performance:
  • Operating Voltage : DC24V
  • Testing Voltage : ±1000v-±100v
  • Temperature  : 25°C±2°C
  • Measuring method  : measure with 20PF, 150mm electrostatic elimination monitor;  30mm Distance, ±1000V - ±100V Decay time
  • Different environments show different test results. The above mentioned is the reference data. Please test according to the actual environmentIonizing Air NozzleHN04 ESDMAN
Installation Method:
Notes
  • The supplied power transformer or DC24V power supply must be used otherwise there is a risk of fire and de-energization. 
  • A pressure-resistant air hose must be used, or the trachea may be broken or air leaking. 
  • Please use it in the following environment, otherwise it may cause damage or reduce the life of this product. 
  • Temperature : 5°C to 40°C; Relative Humidity 35%-65%RH (no condensation). 
  • Excessive pulling of the air hose and power cord is prohibited to avoid damaging the nozzle.
  • Please select the installation place with 100-240V power supply and compressed air.
  • Tracheal Input: For air hose input, please use air hose with pressure-resistant performance (outer diameter: 6mm). 
  • Air: Please connect the compressed air supply hose at the air input port, the pressure is 0.1-0.7mpa, the maximum recommended use is 0.5mpa. Please install the dust filter and filter for oil and water in the air outlet of the compressor. The input air temperature range should be between 5°C to 40°C. 
  • Note: compressed air (CDA) must be used, otherwise the best esd performance cannot be achieved. 
  • Power Transformers: Have to use the supplied power adapter, otherwise it may damage the electrostatic eliminator or cause accident. The attached power supply is only for HN-04 Nozzle Ionizer. 
  • Please do not use it for other purposes.
  • Mounting: Please use M3 flat head screw to fix the Nozzle Ionizer with mounting bracket, and use M3 flat head screw to fix the mounting bracket into proper position. 
  • Grounding: 100-240v power cord must be connected to the power socket connected to the ground wire. Please ensure to grounding correctly according to the rules when using the equipment power supply. Please connect the Nozzle Ionzier to the ground by mounting metal plates. Ionizing Air NozzleHN04 ESDMAN
Ionizing Air NozzleHN04 ESDMANMaintenance:
  • Regular maintenance is very important, please clean regularly according to the following rules. 
  • Emmiter needle will be contaminated after long-term use. 
  • If you do not carry out maintenance and continue to use the air nozzle, the dust adsorption will reduce eliminating statics or cause other malfunction.
  • Therefore, the emitter needle must be cleaned regularly (preferably once every two weeks). 
Notes
a. Do not remove the emmiter needle except to replace it. 
b. Turn off the power supply before cleaning. 
c. The compressed air output switch must be turned off before cleaning. 
d. Do not use solvents or cleaning lotion, otherwise it will cause product cracks, electric shock or other malfunction. 
e. Do not rinse with water, or there will be a risk of electric shock. 
f. In addition to professional maintenance personnel, other users are prohibited to maintain or do modification on the product, otherwise it will cause product failure or electric shock risk.
The Shell Cleaning
Please use a soft clean cloth to wipe the stain on the product, do not use alcohol or thinner solution cleaning.
The Emitter Cleaning
a. Please turn off the power of air nozzle before cleaning. 
b. Unlock the lock button at the tail of the Nozzle, pull out the high voltage generator module. 
c. Clean the emitter tip with a cotton swab dipped in alcohol. Do not use acetone or strong acid solution.
d. Do not apply any external force to the tip of the emitter needle, which may damage the tip. 
e. Replace the emitter immediately if any damage is found. 
f. Power on after the clean liquid has evaporated completely. 
g. Fill in the maintenance contents in the maintenance record. Ionizing Air NozzleHN04 ESDMAN
Replacement of Emitter Needle
Please check the emitter needle at the same time when you clean it.
a. Please use a needle-nose pliers to pull out the old emitter needle when the tip of the emitter needle is found to be damaged, then put the new emitter needle into the holder. 
b. The tip of the emitter needle is very sharp, be careful not to get hurt when replacing it.
c. In normal using environment, the replacement cycle of the emitter needle is one year. But the cycle of replacement will be changed according to the specific using environment. Ionizing Air NozzleHN04 ESDMAN
Troubleshooting Guide:Ionizing Air NozzleHN04 ESDMAN
Product Guarantee:
Our product is produced strictly according to factory quality control procedures,please contact our sales team in the event of any failure
  • The equipment warranty is one year since the product arrived buyer.
  • Warranty coverage: This product is inspected and qualified by our company. During the warranty period, if it shows any damaged or faulty due to poor design or manufacturing, we will providedmaintenance at free cost.
  • The following conditions are out of warranty range:
  • a. Emitter needle is not within the scope of warranty since it is a consumable component. 
  • b. Damage, breakage or malfunction caused by abnormal use.
  • c. Failure caused by modification or disassembly not from our technician
  • d. Failures caused by natural majeure events such as fires, natural disasters, floods, and earthquakes.
  • e. Our company is not responsible for the failure caused by abnormal voltage or external factors.