Product Main

Quick Details

Brand Name: LIYING
Type: microwave
Rating: Medium-scale
Voltage: 380 voltage
Condition: new
Place of Origin: China (Mainland)
Model Number: MDU-3B
Operating pressure: 10 TON
Total power: 115kw

Specifications

the following example is for you reference.


Main Advantages: 

EQUIPMENT ADVANTAGES

 Integrated equipment design, small footprint and low noise.

 the equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.

 Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.

 the medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.

 There are two types of microwave disinfection equipment: fixed and mobile.

 Integrated equipment design, small footprint and low noise.

 the equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.

 Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.

 the medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.

 There are two types of microwave disinfection equipment: fixed and mobile.


  medical waste microwave disposal equipment Mdu3B

 

Technical deta

Equipment Model No.

MDU-3B

Dimensions (L*W*H)

7900mm*2900mm*3300mm

Overall weight

12000kg

Required space (L*W*H)

12000*5000*5600mm

Installed Power

115KW (72KW steam generator included)

Treatment capacity

180kg/h (±10%) 

(medical waste density average 0.1Kg/l~0.15kg/l)

Operation and control

PLC control, automatic process

Shredding system

Four-shaft shredder, automatic reverse system is configured to avoid material blockage.

Feeding form

Automatic lifting and charging system contained

Disinfection temperature

≥95℃

Disinfection duration

≥45min

Disinfection effect

≥4 log10

the treatment effect test uses Bacillus subtilis var. Niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 4.00.

Microwave frequency

2450+/-50MHz

Microwave generator power

1.25KW *8unit

Manpower

No specialized operator / ONE


medical waste microwave disposal equipment Mdu3B