Brand Name: | LIYING |
---|---|
Type: | microwave |
Rating: | Medium-scale |
Voltage: | 380 voltage |
Condition: | new |
Place of Origin: | China (Mainland) |
Model Number: | MDU-3B |
Operating pressure: | 10 TON |
Total power: | 115kw |
Quick Details
Specifications
the following example is for you reference.
Main Advantages:
EQUIPMENT ADVANTAGES
Integrated equipment design, small footprint and low noise.
the equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.
Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.
the medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.
There are two types of microwave disinfection equipment: fixed and mobile.
Integrated equipment design, small footprint and low noise.
the equipment has a high degree of automation, and only one person is required to operate a complete set of equipment, saving labor costs.
Low energy consumption, the whole set of equipment only needs electric drive, taking 5t per day as an example, the total installed power is only 117 kilowatts.
the medical waste treatment method is flexible. When there is medical waste to be processed at any time, the equipment can be turned off after the treatment is completed, which minimizes energy loss and personnel wages and saves treatment costs.
There are two types of microwave disinfection equipment: fixed and mobile.
Technical deta Equipment Model No. MDU-3B Dimensions (L*W*H) 7900mm*2900mm*3300mm Overall weight 12000kg Required space (L*W*H) 12000*5000*5600mm Installed Power 115KW (72KW steam generator included) Treatment capacity 180kg/h (±10%) (medical waste density average 0.1Kg/l~0.15kg/l) Operation and control PLC control, automatic process Shredding system Four-shaft shredder, automatic reverse system is configured to avoid material blockage. Feeding form Automatic lifting and charging system contained Disinfection temperature ≥95℃ Disinfection duration ≥45min Disinfection effect ≥4 log10 the treatment effect test uses Bacillus subtilis var. Niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 4.00. Microwave frequency 2450+/-50MHz Microwave generator power 1.25KW *8unit Manpower No specialized operator / ONE