Product Main

Quick Details

Brand Name: CAPNOMED
4: 4

Specifications

 Sensor

Complete model: Compatible with equipment from many well-known manufacturers around the world, with wide compatibility;

 

Using medical TPU plastic and low impedance wire: It has the advantages of good texture, bending resistance, corrosion resistance, and stable waveform;

 

Gold-plated nickel-plated equipment end connection hardware and electrode surface: Excellent electrical conductivity, ensuring full contact and reliable connection;

 

Using imported electronic components: It has the advantages of accurate value and stable waveform.

 

Specification of     Sensor

Project

Specifications

Principle of Operation

Non-dispersive infrared(NDIR) single beam optics, dual wavelength, no moving parts.

Initialization Time

Capnogram displayed in less than 3 seconds, full specifications within 3 minutes(At 25°C)

CO2 Measurement Range

0 - 114 mmHg; 0 - 15 %; 0 - 15.2 kPa

CO2 Rise Time

Rise Time Less than 80 ms

CO2 Resolution

0.1mmHg 0 to 38 mmHg.

0.25 mmHg 39 to 114mmHg.

CO2 Accuracy

0 - 40mmHg ±2 mmHg.

41 - 76mmHg ±5% of reading.

77 - 114 mmHg ±8% of reading.

above 80 breaths per minute ±12% of reading.

* Note: Gas temperature at 25°C.

CO2 Stability

Short term drift: Drift over four hours shall not exceed 1 mmHg maximum.

Long term drift: Accuracy specification will be maintained over a 120-hour period.

Sampling Frequency

100Hz.

Respiration Rate Range

3 to 150 breaths per minute.

Respiration Rate Accuracy

±1 breath.

Temperature

Operating: 0 to 40°C; Storage: -40 to 70°C; Transport: -40 to 70°C.

Humidity

Operating: 10 to 90% RH, non-condensing; Storage: 10 to 90% RH, non-condensing. Transport: 10 to 90% RH, non-condensing.

Atmospheric Pressure

Operating: 400-800 mmHg; Storage: 400-800 mmHg; Transport: 400-800 mmHg.

Water Resistance

IPX4 - Splash-proof - Sensor only.

Sensor Weight

<250g

Sensor Size

Deep*Wide*High: 102mm*62mm*38mm

Cable Length

0.75m

 

Details of Sidestream Capnography Sensor

Quick Details of Sidestream Capnography Sensor

Designed for use with monitors and ventilators equipped with a carbon dioxide function, it accurately and swiftly collects end-tidal carbon dioxide values and generates visual curves. both reusable and disposable consumables are available.

 

If you want to know more kinds of sidestream capnometer, please visit our website.

Now the price of Is reasonable, anything you need, please contact us.


Sidestream Capnography Sensor gas sampling line