| Brand Name: | Supmea |
|---|---|
| Accuracy: | 1~2.5% |
| Power Supply: | 220V, 24V |
| output: | 4-20mA,Pulse,RS-485,HART |
| Medium: | Various gases (except acetylene gas) |
Quick Details
Specifications
the thermal gas mass flowmeter is designed according to the principle of thermal diffusion. The instrument uses the constant temperature difference method to measure the gas accurately. It has the advantages of small size, accurate measurement, high digitization, and easy installation. The mass flowmeter for gas flow measurement without temperature and pressure compensation is an accurate measurement. The mass flow rate or standard volume flow rate of the gas can be obtained. Compressed air/gas in the boiler room or dryer/carbon dioxide gas in distillery/methane gas in the sewage treatment plant and aeration/generated gas (such as argon, nitrogen, carbon dioxide, helium, oxygen)/gas leak detection.
Easy installation and maintenance. under certain conditions, it can be installed and maintained without stopping production
Digital design and LCD liquid crystal display. Overall digital circuit measurement, accurate measurement, easy maintenance
RS-485 communication, or HART communication, can achieve factory automation and integration
220V, 24V power supply; It has split structure and integrated structure
PErformance |
Technical Parameters | |
Struct |
Plug-in |
Pipeline |
Media |
Various gases (except acetylene gas) | |
Pipe Range |
DN100~2000mm |
DN15~300mm |
Flow range |
0.1~120Nm/s | |
Accuracy |
±1~2.5% | |
Temp |
Sensor:-40~+160°C,Convertor: -20~+45°C | |
Pressure |
Media Pressure≤2.5MPa | |
Power |
DC24VorAC220V≤18W | |
Reaction |
1s | |
Output |
4-20mA,Pulse,RS-485,HART | |
Alarm |
2relay(keep open),10A/220VAC,5A/24VDC | |
Display type |
Carbon steel, stainless steel, plastic, etc. | |
Material |
M20X1.5;NPT1/2 | |
Display |
LCD | |
Contents |
Mass flow, volume flow, cumulative flow, time, running time, standard flow rate | |
Protect |
IP65 | |
Sensor |
Stainless steel,Carbon steel | |

