Brand Name: Supmea
Accuracy: 1~2.5%
Power Supply: 220V, 24V
output: 4-20mA,Pulse,RS-485,HART
Medium: Various gases (except acetylene gas)

Specifications

Digital Thermal Gas Mass Flow Meter with LCD High Accuracy Gas Mass Flow Measurement
the thermal gas mass flowmeter is designed according to the principle of thermal diffusion. The instrument uses the constant temperature difference method to measure the gas accurately. It has the advantages of small size, accurate measurement, high digitization, and easy installation. The mass flowmeter for gas flow measurement without temperature and pressure compensation is an accurate measurement. The mass flow rate or standard volume flow rate of the gas can be obtained. Compressed air/gas in the boiler room or dryer/carbon dioxide gas in distillery/methane gas in the sewage treatment plant and aeration/generated gas (such as argon, nitrogen, carbon dioxide, helium, oxygen)/gas leak detection.


Easy installation and maintenance. under certain conditions, it can be installed and maintained without stopping production
Digital design and LCD liquid crystal display. Overall digital circuit measurement, accurate measurement, easy maintenance
RS-485 communication, or HART communication, can achieve factory automation and integration
220V, 24V power supply; It has split structure and integrated structure


PErformance

Technical Parameters

Struct

Plug-in

Pipeline

Media

Various gases (except acetylene gas)

Pipe Range

DN100~2000mm

DN15~300mm

Flow range

0.1~120Nm/s

Accuracy

±1~2.5%

Temp

Sensor:-40~+160°C,Convertor: -20~+45°C

Pressure

Media Pressure2.5MPa

Power

DC24VorAC220V≤18W

Reaction

1s

Output

4-20mA,Pulse,RS-485,HART 

Alarm

2relay(keep open),10A/220VAC,5A/24VDC

Display type

Carbon steel, stainless steel, plastic, etc.

Material

M20X1.5;NPT1/2

Display

LCD

Contents

Mass flow, volume flow, cumulative flow, time, running time, standard flow rate

Protect

IP65

Sensor

Stainless steel,Carbon steel