Product Main

Specifications

12 LEAD 24 HOURS HOLTER SYSTEM This product is based on 3 lead system combined with the most advanced international electronic technology. The FLASH MEMORY with super-storage capacity applied in the recorder really realizes 12 lead 24 hours continuous synchronous non-compression recording. It ensures the reliability and the high precision of the recording. It?s more exact than 3 lead system in diagnosing arrhythmia, hypertrophy of myocardium and locating and quantifying the lack of blood in the coronary arteries, so it has much better clinical application. 12 lead Holter-star system also has multi-function include HRV, QTD, and QTC besides common arrhythmia and ST segment analysis. In addition, the methods of time domain, frequency domain and non-line HRV analysis meet the international standard. System Standard Configuration: · 1 commercial PC · 1 Laser Jet printer · 2 12 channel ECG recorders · 2 12 channel Holter cables · 1 Analysis software pack System Characteristic: · Record channel: 12 channel (I, II, III, aVR,aVL, aVF, V1, V2, V3, V4, V5, V6 ) ECG · Optional manual and automatic operating mode · Display the instant heart rate · Review function of 24 hours ECG analysis results · 12 channel 24 hours ST segment deviation analysis and display · Display 12 channel 24 hours ST segment deviation per minute · Display the lack of blood ST Index · Pre-scan function of ECG wave process in ahead of analysis · Measurement function of QTD and QTC · Comply with the international standard HRV analysis in time domain, frequency domain and non-line HRV Technical Specification: · Dynamic input range:?5mv · Response Frequency: 0.05-60Hz · Sampling Frequency: 125Hz · Gain: x0.5 x1 x2 (10mm/mv) · Common-mode Ratio: >95dB · Flash Memory Capacity: 128MB · Power: 1AA LR6 battery 3 LEAD 24 HOURS HOLTER SYSTEM Landcom brand 3 lead Holter ECG system, cooperated with Tisnghua University, received warmly welcome by consumers since it was promoted to market. In 1997, the product was named as ?National New Product? by National Economy & Trade commission as well as the standard instrument for normal HRV value measurement by Chinese Medical Association. The system offers precise detection method for Sinus Tachycardia, Sinus Bradycadia, Pause, Arterial fibrillation, all kinds of Block and ST events. The system can edit the ECG template after the beats remarked and modified, so it avoid loss and false labeled in the process of analysis. 3 lead Holter system is chosen as standard of domestic HRV research by Chinese Medical Association as well as the national new product by the National Economy & Trade commission. Technical Specification: · Record channel: 3 channel · Record Time: 24 hours · Capacity: 48MB · Common-mode Ratio: >60dB · Response Frequency: 0.05-40Hz · Sampling Frequency: 128Hz · Gain: ?1 (10mm/mv) · Power Supply: 1AA LR6 battery · Size: 120?67?23mm3 · Weight: 125g (without battery) System Characteristic: · Operate on Chinese windows98 platform · Having analysis ability of arrhythmia, ST segment deviation and HRV · Optional manual and automatic operating mode · Ability of pre-can ECG · Review function of 24 hours ECG analysis result · 3 channel 24 hours ST segment deviation analysis and display · Display 3 channel 24 hours ST segment deviation per minute and lack of blood of Index · Comply with the international standard HRV analysis in time domain, frequency domain and non-line HRV System Standard Configuration: · HS-3 recorder