Specification:
Power Source: 100~130V/AC, 220~240V/AC
Power Frequency: 50-60Hz
Ambient Light: <10Lux~2000Lux(adjustable)
Rated Load: 60WX2(Max) PAR38 or PAR20
Detection Range: 180?
Detection Distance: 12m (<22℃)(adjustable)
Time Delay: 5Sec.~8Min.( adjustable)
Work Temperature: -20~+40℃
Power Consumption: 0.45W(static 0.1W)
Installation Height: 1.8~2.5m
I P44
ST66 INFRARED SENSOR LAMP
INSTRUCTION
GENERAL
This product is an energy-saving sensor lamp, which can turn on when one comes and turn off when leaves. It can identify day and night automatically. It adopts infrared energy discharging detector, IC and SMD technology itsperformance is stable and reliable. When one enters the detection field and trigger it, the infrared sensor will work and make the lamp on. When leaves, the lamp will die out automatically.
FUNCTION
It can identify day and night automatically, the ambient light of starting operation can be adjusted freely, it can work at night and stop in the daytime, it can be adjusted by users;
Adjustable detection distance: It can be adjusted according to using location;
Adjustable time-delay: It can be adjusted according to the local place;
Time-delay is added continually, if one moves in detection field when the lamp is on, the light time will compute once more on the basis of the last induction抯 rest and delay the light time automatically.
SPECIFICATION
Detection distance(<24℃): 2~11m
Detection range:180?
140?
Power sources:180~240V/AC
100~130V/AC
Power frequency: 50~60Hz
Ambient-light:<10~2000Lux
Delay-time: 5S~7min?min
Rated Load:75W?(max)
Installation height: 1.8m~2.5m
Working temperature:-20℃~+40℃
Working humidity: <93%RH
WIRING FIGURE
Brown 朙ive
Blue- Neutral
Green/Yellow---Earthing
INSTALLATION
Connect the power source into the lamp according to connection-wire diagram (on the right) when you install it,
Select the specific installation position according to the following diagram
The detection angle (top view)
The strong detection field (arrow means one抯 moving direction)
Poor detection field
Detection distance and range (side view)
Installi