Specification:
Rated Voltage: 220/ 230/ 240V
Rated Frequency: 50/ 60Hz
Tariff option: Programmable 4 tariffs(sharp, peak, shoulder and off-peak),
10 day-periods, 2 time zones(customization available via software programming)
Communication interface: Infrared or RS485 port
Anti-tampering: Simultaneous sampling of phase current and neutral current
Basic Current (Max. Current): 1.5(6)A, 2.5(10)A, 5(20)A, 5(30)A, 5(40)A, 10(50)A, 10(60)A, 10(80)A, 10(100)A, 20(80)A, 20(120)A
Current range: 1.5-120A
Overload Capacity: 4-10 lb
Starting current: 0.4-l0lb(Class 1.0), 0.5-lb(Class 2.0)
Power Consumption: <=2W /5VA (total)
Impulse Output: 80ms
Time accuracy(day error): within 0.5seconds/day
Data backup battery voltage: 3.6C(DC)
Battery capacity: 1000mah
Data memory: EPROM
Type of connection:
Meter board connection, through case
Nos. of wires: two wires
Register: LED display (option) / LCD display (option)
Running with no load: built-in anti-running logic design
Meter's Constant(imp/kWh): 6400,3200,1600
Limit temperature range of operation: -25centigrade to 55centigrade
Annually average relative humidity: <=85%
Dimension: 132x110x55(mm)
Accuracy: Class 1.0 or 2.0
Product life (MTTF): 15 years