1) Input specifications:
a) Input voltage: 110-230V AC 5% (90V AC - 264V AC)
b) Input frequency: 50 / 60Hz 10% (45Hz-66Hz)
c) Fuse: A fuse is included in the AC line circuit. The fuse rating
is as to prevent hazard in the event of an intenal failure of
the power supply.
d) Inrush current: <20A/ms
e) Earth leakage current: the earth leakage current does not exceed
0.25mA at 264V AC 66Hz input and the minimum load condition
f) Efficiency: 75% min., at 220V AC input full load test
2) Output specifications:
a) Output voltage:
Output 1: +3.30v / 100-2000mA/+3.14V-3.46V (voltage limit)/5% tolerance
Output 2: +5.00/0-1000mA/+4.75-5.25 (voltage limit)/5% tolerance
Output 3: +12.0/20-500mA/+11.4-12.6 (voltage limit)/5% tolerance
Output 4: +24.0/20-100mA/+21.6-26.4 (voltage limit)/7% tolerance
Output 5: +30.0/0-100mA/+27.0-33.0 (voltage limit)/5% tolerance
b) Output ripple:
Measurement of ripple includes a 0.1uF ceramic capacitor and a 47uF
electrolytic capacitor at the output of measuring oscilloscope
Line ripple: measured with an oscilloscope with a bandwidth of 100MHz
Switching ripple: measured with an oscilloscope with a bandwidth of 100MHz
Output 1/2: 30mV at peak-peak line ripple; 200mV at peak-peak switching
ripple
Output 3/4/5: 60mV at peak-peak line ripple; 200mV at peak-peak switching
ripple
c) Turn on delay time: 1S max., at normal line full load
d) Hold on time: 20mS min., at 220Vac line max load
e) Over current protection: the power supply protects itself from any
over current condition
f) Thermal protection: the power supply protects itself down if it
overheats. It resets itself with no operator invention
g) Shorted output
h) Hi-pot test: dielectric withstanding voltage AC input. N to all output
connectors 3,000V AC for 1-minute test
i) Burn-in: all power supplies will go through 4 hours of burn-in at
40 temperature chamber under the nominal input and 80% of the
maximum load condition, before delivery to AMP
j) PCB dimensions and weight: 165 x 70 x 45(L x W x H), 0.20kg max.